im-tek.com

Fisher OSE Slam-Shut Valve

Fisher

Product Code: OSE
Brand: Fisher



GET OFFER: info@imtek.com.tr

Description for Fisher OSE Slam-Shut Valve

Fisher™ Type OSE Slam-Shut ValveType OSE slam-shut valve is used to rapidly cut the gas flow during an overpressure or underpressure event. It is ideal for gas applications requiring positive shutoff protection, tight accuracy, faFeaturesOverpressure and Underpressure ProtectionHigh Shock and Vibration Resistance - Type OSE incorporates a two-stage tripping mechanism that significantly reduces nuisance tripping caused by vibrations or inlet pressure variations commonly experienced by other shut-off valves.High Accuracy - Maintains up to ±1% accuracy regardless of inlet pressure, flowrate and the size of the slam-shut.Easy In-Line Maintenance - Top entry design reduces maintenance time and manpower requirements; parts can be inspected and replaced without removing the body from the line.Water Tight - Type OSE is water tight to 10 ft / 3.0 m.Positive Shutoff - After closing, the slam-shut valve stays closed until the system is shut down and the valve is manually reset. An O-ring on the valve plug seal provides tight shutoff.Remote Alarm Capability - A limit switch is available that detects when the Type OSE slam-shut valve is tripped.SpecificationsBody Sizes and End Connection StylesWCC Steel: 1 and 2 NPT; NPS 1, 2, 3, 4 and 6 / DN 25, 50, 80, 100 and 150; CL150 RF, CL300 RF or CL600 RFLCC Steel: NPS 8 and 10 / DN 200 and 250; CL150 RF, CL300 RF or CL600 RFCast Iron: 1 and 2 NPT; NPS 1, 2, 3, 4 and 6 / DN 25, 50, 80, 100 and 150; CL125 FFPressure RatingsMaximum Inlet Pressure: 101 bar / 1470 psig or max. body ratingMaximum Set Pressure: 101 bar / 1470 psig or max. body ratingMinimum Set Pressure: 10 mbar / 4.02-inches w.c.Maximum Shutoff Pressure Differential 100 bar / 1450 psigManometric Sensing Device SpecificationsSpring Ranges: 10 mbar to 72,9 bar / 4.02-inches w.c. to 1058 psigMaximum Sensing Inlet Pressure: 72,9 bar / 1058 psigSetpoint Tolerance: 0,004 bar / 0.058 psig to 12,0 bar / 174 psigMaximum Difference Between Overpressure and Underpressure: 33,0 bar / 479 psigTemperature Capabilities-30° to 82°C / -22° to 180°FPressure Sensing Connections1/4 NPTOptionsExplosion-proof switchNon-explosion-proof limit switchSolenoidAdditional manometric device for extra pressure sensingst speed of response, and high shock and vibration resistance. The top entry design makes in-line maintenance easy, saving time and manpower requirements.

Recommended Products For Fisher


Fisher 546 Series Electro-Pneumatic Transducers
Fisher TBX-T Desuperheater
Fisher CS400 Pressure Reducing Regulator
Fisher 92C Self-Powered Control Valve
Fisher R8 Sanitary Backpressure Regulator
Fisher 8580 High Performance Butterfly Valve
Fisher 846 Electro-Pneumatic Transducer
Fisher 3024C Pneumatic Diaphragm Actuator
Fisher Cavitrol™ III Trim
Fisher 2100 Pneumatic and 2100E Pneumatic and 2100E Electric Liquid Level Switches
Fisher C1 Pneumatic Controller and Transmitter
Fisher ZL Series Pressure Reducing Regulator for Low Pressure Applications
Fisher V150E Control Valve
Fisher V270 Full-Bore Ball Control Valve
Fisher H284 and H5114 Series Large Internal Relief Valves
Fisher CAV4 Valve
Fisher HP and EH Globe and Angle Valve
Fisher 630R Relief Valve
Alfa Laval TE67A110002020 FT: 8 m³/h,4-20 mA/pulse without display,Clamp 1",N/A
Elecnova PD194E-9HY Multimeter
FIP Italy VXEFV Series DN 65÷100 Easyfit 2-way Ball Valve
Officine Orobiche 132/2 Flowmeter
PCM 40A12CT API 676 Progressing Cavity Pumps
HFB GUF 517 Plummer Block Housing
Micro Detectors C30P/BP-2E Proximity Sensor
Edur NU1002E150L-2900 Multi-Stage Centrifugal Pump
HFB SSNI 511 Plummer Block Housing
Kadant 995.415/0001 RX Rotary Union
Grundfos DMX 50-10 B-PVC/V/C-X-E1I007XEMNG Dosing Pump
Italvibras MTF 10/10000-S02-ACC 602498 Axial Coupling Flanged Electric Vibrator
KSB UPHA 293/06A+HBC 253 6.0 SQMM S.D. Pump
Alfa Laval 9613363210 UNIQUE SSV DN-50 220 W-W 0.8/BLASTED EPDM CHANGE OVER TWO STEP NO MAINTAINABLE
Kadant 995.143/0001 RX Rotary Union
Mp Filtri CU1102M90HNP01 Filter
Stahl 8146/5-V11d07-00-0000-0 Load Disconnect and Manual Transfer Switch
SKF 178-600-015+924, 24 VDC Piston Pump Unit Motor
Grundfos NK 40-250/219 AA1F2AESBAQEHW3 Pump
NSD VS-212DN-R3 Motion Controller
ETP MINI R-12 Hub-Shaft Connection
Faggiolati X418R2C2-S100LA5 Pump
FIP Italy VKRDF Series DN 10÷50 DUAL BLOCK® Regulating Ball Valve
Dafram R1FP Ball Valve