Produktname: JCT FTC130-TRA Thermal Conductivity Detector
Marke: JCT
Produktcode: FTC130-TRA
Stichwörter: JCT
FTC130-TRA Thermal Conductivity Detector
Thermal
JCT FTC130-TRA Thermal Conductivity Detector
JCT Thermal Conductivity
JCT FTC130-TRA Thermal Detector
JCT FTC130-TRA Thermal
FTC130-TRA Detector
JCT FTC130-TRA
FTC130-TRA Thermal
JCT Conductivity
JCT Conductivity Detector
JCT FTC130-TRA Thermal Conductivity
JCT FTC130-TRA Thermal Conductivity Detector
Thermal Conductivity Detector
FTC130-TRA Thermal
FTC130-TRA
JCT Detector
JCT Conductivity Detector
Thermal Conductivity Detector
Interessieren Sie sich für das Produkt JCT FTC130-TRA Thermal Conductivity Detector vom Hersteller JCT mit dem Code FTC130-TRA? Kontaktieren Sie uns jetzt und holen Sie sich ein Angebot. Imtek Engineering, der schnellste und zuverlässigste Lieferant von Industrieausrüstung der Welt, wird Ihnen das beste Angebot machen!
Angebot per E-Mail erhalten: info@im-tek.com
Holen Sie sich jetzt ein Angebot für JCT FTC130-TRA Thermal Conductivity Detector von unserem Live-Support-Team!
ApplicationsExtractive gas analysisQuality and process monitoringContiuous concentration determination of single gas components e.g. H2, CO2, O2, HeFor the H2-measurement at heat treatment in the metal industryFor the H2-measurement in miniplantsBenefitsPrecise and long-term stable thermal conductivity measurementIndependent of gas flow and gas pressureHigh sensitivity independent of the ambient temperatureFast response time (T90 approx. 1 s)Pressure resistant gas paths out of stainless steel (10 bara)Robust tight aluminium housing (IP65)Small dimensionsLinear signal output 4 to 20 mAEasy calibration with covered push buttonsFactory configuration and calibrationFeaturesBased on micromechanic silicon chipDetector mounted in a stainless steel housingStainless steel housing and electronic mounted in a sealed aluminium housingOperation of the detector with two heating elements and a temperature sensor at constant 63?°CGas concentration corresponds to required compensation energy, depending on cooling of the chip due to varying thermal conductivityEspecially good measuring results are achieved under following conditions:at binary gas mixtures, e.g. CO2 in N2, O2 in Ar or H2 in N2if only two gas components at multi component mixtures vary in concentration, e.g. CO2 in airif the measured component has a significantly different thermal conductivity than the remaining gas components, e.g. H2, He, or in a mixture of O2 and N2