Produktname: Megger TTR550005B Transformer Turns Ratio Test Set
Marke: Megger
Produktcode: TTR550005B
Stichwörter: Megger
TTR550005B Transformer Test
Megger TTR550005B Ratio
Megger TTR550005B Transformer Set
Megger TTR550005B Transformer
Turns Ratio
Megger TTR550005B Transformer Turns Ratio Set
Test Set
Megger TTR550005B Transformer Turns
Megger TTR550005B Transformer Turns Test
Transformer Turns Set
Megger Test Set
Transformer Ratio Test Set
Megger Turns Set
Transformer Ratio Test Set
Transformer Turns Ratio Test Set
TTR550005B Test
Megger TTR550005B Transformer Turns Ratio
Transformer Ratio Set
Megger Transformer Test
Megger TTR550005B Turns Test Set
Transformer Turns Ratio Test Set
Interessieren Sie sich für das Produkt Megger TTR550005B Transformer Turns Ratio Test Set vom Hersteller Megger mit dem Code TTR550005B? Kontaktieren Sie uns jetzt und holen Sie sich ein Angebot. Imtek Engineering, der schnellste und zuverlässigste Lieferant von Industrieausrüstung der Welt, wird Ihnen das beste Angebot machen!
Angebot per E-Mail erhalten: info@im-tek.com
Holen Sie sich jetzt ein Angebot für Megger TTR550005B Transformer Turns Ratio Test Set von unserem Live-Support-Team!
Used for testing single phase power and distribution transformers Design based on precision bridge measuring technique Unmatched accuracy (±0.1%) in a portable design The Single Phase TTR, Transformer Turns Ratio Test Set, measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit. The TTR test set aids in identifying: Shorted coils Open circuits Incorrect connections Internal faults or tap-changer defects in step regulators as well as in transformers The instrument measures highly sensitive turns ratios of up to 129.99:1 with accuracy of ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1. The TTR set operates on the principle that the voltage ratio of the transformer at no load is practically equal to the true turns ratio. The major source of error in a transformer is a primary impedance drop due to magnetizing current, which is kept to a minimum by excitation at a fraction of rated voltage. By employing a design that meets both of these conditions along with the use of a null balance system, the turns ratio of a transformer can be determined accurately. When measuring the turns ratio of distribution and power transformers, the accuracy is well within 0.1%.