im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco MDT462F-1/2-5C-15/46-A Melt Pressure Transmitters
Dynisco TDT463F-1/2-3,5C-15/46-A Pressure Sensors
Dynisco PT291-6K4,8 B906 Pressure Sensors
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco ATC990-4-0-1-1-0-1-000 Process Controller
Dynisco MDT462F-1/2-2C-15/46-B171 Melt Pressure Transmitters
Dynisco MDA462-1/2-5C-15/46 Pressure Sensors
Dynisco PT462E-15M-6/18 Pressure Sensors
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco MDT462F-M18-7C-15/46-A Melt Pressure Transmitters
Dynisco PT-242FM-35M Pressure Sensors
Dynisco MDT420F-1/2-1M-15-SIL2 Melt Pressure Transmitters
Dynisco PT160-3M-H3 Pressure Sensors
Dynisco ECHO-MA4-MPA-R21-M14-6PN-S06-F18-NTR Melt Pressure Sensors
Dynisco MDT 462F-1/2-3,5C-15/46-T80 Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Dynisco PT4624-15-M-6/18 Pressure Sensors
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Stauff 1910000401 Pressure Gauge Spg-063-00400-01-P-B04
Emotron FLD48-004-54 Drive
HFB EK 200 A Plummer Block Housing
Eurotherm 690PC/0055/400/0010/UK/0/0/0/SHTTL/B0/0/0 Drive Eurotherm 690PC/0055/400/0010/UK/0/0/0/SHTTL/B0/0/0 Drive
Scherzinger 5040-210-B-DM-150-2 Hastelloy (R) Gear Pumps 5040
Goldammer TR15K1-A-800 Temperature-capillary tube-regulator
CMO Serie HD Hydraulic Valve
Gefran LT-B-0500-P 0000X000A0N Potentiometer
Greisinger GDUSB1000 Adapter
Mahle Pi 51025-057 78336323 Duplex Filter
Alfa Laval 9612628271 LKB-2 DN25 DIN M/M EPDM 316L KIT HANDLE 1.1 W/2 POS TYPE A
Enerpac HCG2006 Hydraulic Cylinder
Buschjost 859 0226.8000.02400 Way Pulse-solenoid Valve
Pall UR689CD6440ZG Duplex Filter
VISHAY BLH KIS-1 Weigh Module
Ebara 32-160/1.5 Centrifugal Pump
Aviteq UVD 5Y Unbalance Motor
Indexator 8000308 IR 10M M20 Rotator
Rotork IQTF Electric modulating Actuator
Stauff SP-428-AL-DP-AS-M-W10 COLLARE ALL. D.28 COMPLETO DI VITI E PIA
Aryung ACH 4-30-F Coolant pumps
Hengstler RI58-O/10000AS.41TB Encoder
Gefa AT200 R Knife Gate Valve
Habasit CNW-5E-A1 Food Belt