im-tek.com

Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco MDA462-1/2-5C-15/46 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensors
Dynisco MDT420CAN-/2-2C-15-HA51 Melt Pressure Transmitters
Dynisco PT4624-10M-6/18-SIL2 Pressure Sensors
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Dynisco TDT432F-1/2-3.5C-15/46-SIL2 Pressure Sensors
Dynisco PT4624-35MPA-6/18-SIL2 Pressure sensors
Dynisco 1490-4-0-0-0-0 Panel Indicator
Dynisco IDA354-3,5C-10V-S78B Pressure Transmitters
Dynisco IDA334-1M Pressure Transmitters
Dynisco UPR900-2-1-0-1-0-0-0-0 Process Indicator
Dynisco PT160-5M Pressure Sensors
Dynisco FMMX-5CK-6/30 Melt Monitor Alarm
Dynisco MDA462-1/2-5C-15/46-B171 Pressure Sensors
Dynisco UPR900-2-1-1-1-0-0-0-0 Process Indicator
Dynisco MDT422T-1/2-3,5C-15/46A Melt Pressure Transmitters
Dynisco MDT422F-1 / 2-3.5C-15/99-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-1-2-3,5C-15-46 Melt Pressure Transmitters
Aron AD3E02EY003 Cetop 3 Valve All Ports Open 230V AC
Goulds 3700LFI API 610 Process Pump
Greisinger GNS-SCV-W Protective Device
Hengstler AC58/0010AF.46SBA Absolute Encoder
Alfa Laval TE67E931111220 PT: 0 to 25 bar 0,1% FS flange DN40,gland M20,N/A
Albrecht ASV-P/MKA Production series Compact Systems
Westcode N1132NC300 Phase Control Thyristors-Capsule
Hengstler AC58/0010EF.47I2B-B5-C Absolute Encoder
Control Techniques 190 U3B 200 VAAEA Motor
Woerner VPB-H Progressive distributor
Valco SAFE POT Safety Barrier
MBS MLD 60 3 18 1 1000 Mixflo Multitube Demontable Heat Exchanger
Sed Type 600 Pilot Solenoid Valve
Ebara COMPACT BM/126 Multi-Stage Centrifugal Pump
Goulds RSU Axial Flow
Meister RVM/U-L20090 Flow Monitor For Gases
Gefran LT-H-0175-P L000X000N00 Potentiometer
Gefran LT-F-0225-P L000X000X00 Potentiometer
Aron ADC3E03CMUR1 Valve
Greisinger GIM3090 Infrared Thermometer
Faulhaber 20/1R 23:1 Planetary Gearhead
Italvibras MVSI 075/22000-S90 602873 Electric Vibrator
Nuovafima TG8 DN100-150
Inoxihp PF 480 Series Horizontal Quintuplex Plunger Pumps