im-tek.com

Dynisco ECHO MA4 MPA R23 UNF 6PN S06 F18 NTR Melt Pressure Sensors

Dynisco

Product Code: ECHO MA4 MPA R23 UNF 6PN S06 F18 NTR Melt Pressure Sensors
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO MA4 MPA R23 UNF 6PN S06 F18 NTR Melt Pressure Sensors

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco TDT432F-1/2-5C-46/46-S147-A Pressure Sensors
Dynisco PT462E-1/2-1M-6/18 Pressure Sensors
Dynisco 1490-2-1-1-0-0 Panel Indicator
Dynisco PT 415D-5M-6-B314-B173 Pressure Sensors
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco ECHOE22611122 Melt Pressure Sensors
Dynisco MDA462-1/2-1M-15/46 Pressure Sensors
Dynisco TDT432F-1/2-3.5C-15/46-SIL2 Pressure Sensors
Dynisco DYMT-S-1/2-J-25-23-G Melt Temperature Probe
Dynisco TDT432F-1/2-5C-46/46-S137-SIL2 Pressure Sensors
Dynisco MDT 422F-1/2-3.5C-15/46-B171-B173-SIL2 Melt Pressure Transmitters
Dynisco PT462E-1/2-10M-6/18 Pressure Sensors
Dynisco ATC990-4-1-1-1-0-1-0-0-0 Process Controller
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco MDT420CAN-/2-2C-15-HA51 Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
RSG 92701330 270A1500/10/V4G38F Solenoid Valve
Joyce/Dayton SA5536C450 Solar Tracking Actuator
Honsberg LABO-VHS-032INS Flow Transmitter
Olaer 19029800225 Bladder Kit 2.5 L
Vogel MKF2-12DC01000 429 Single Line Pump
Barksdale D1X, D2X Series Explosion Proof Diaphragm Switch
Power Genex ESV-D Solenoid Valve
Olaer EHV 32-330/90 Bladder Kit
Bollfilter 3532219 Gasket
Honeywell ML7420A8088 Proportional Linear Valve Motor
Honsberg HD2K-020GM015 Flow Switch
Moog D662-4308K P01HAMO6VSX 2-A Servo Valve
Ham-let Tube Buttweld H-500 Three Piece Ball Valve
Parker 15P105QBE2KS124 Duplex Filter
Vogel MKU1-13AD02000 924 Single Line Pump
Stenflex Type B-2 DN 32 Expansion Joint
Spirax Sarco BSA3 PN25 DN200 Metal Bellows Valve
Hengstler AC58/0010EQ.72DPZ Absolute Encoder
Atos SC LI-25374 Valve
Tokimec DG4VS-5 Shockless Solenoid Operated Directional Control Valves
Bühler BFP Circular Pumps
Alfa Laval 9612628506 LKB-2 DN80 DIN M/W EPDM 316L KIT ACT LKLA-T Ø85 NC 6MM
Ifm II5448 Inductive sensor
Grundfos NK 125-225/218 AA1F1S3ESBQQEJW5 Pump