im-tek.com

Dynisco ECHO-MA4-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Sensors

Dynisco

Product Code: ECHO-MA4-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pessure Sensors
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MA4-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Sensors

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco UPR90031100100 Process Indicator
Dynisco PT460E-5M-9 Pressure Sensors
Dynisco 462H0002 Pressure Sensor
Dynisco DYMT-S-1/2-2xPT100/4-15-15-G Melt Temperature Probe
Dynisco DYMT-S-1/2-J-25-23-G Melt Temperature Probe
Dynisco MDT462F-1/2-3,5C-15/46A Melt Pressure Transmitters
Dynisco PT462E-7CB-6/18 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-T80-SIL2 - Melt Pressure Transmitters
Dynisco PT4624-15-M-6/18 Pressure Sensors
Dynisco TPT4636-M14-50MPA-6/18-TC6 Pressure Sensors
Dynisco PT4624-5M-6/18-SIL2 Pressure Sensors
Dynisco 462F0149 Pressure Sensor
Dynisco ECHO-MV3-MPA Melt Pressure Transducers
Dynisco PT 131B-M14-50MPA 150/370-K Pressure Sensors
Dynisco TDT432F-1/2-5C-46/46-S147-SIL2 Pressure Sensors
Dynisco PT462E-15M-6/18 Pressure Sensors
Dynisco TDT432F-1/2-5C-46/46-S137-SIL2 Pressure Sensors
Dynisco ATC990-401111000 Process Controller
Heidenhain ID:1119971-01 HR 510 .. without detent Portable Electronic Handwheel
Yuken DSHG-04-3C2-D24-N1-46 Valve
Dynisco ATC990411101000 Process Controller
Olaer EHV 1-350 / 00-A25BB-200 Bladder Accumulator
Saip APV0.35 Plastic Accumulator
MBS MLD 168 88 12 1 1000 Mixflo Multitube Demontable Heat Exchanger
Habasit T07/U Blue SQ EMB TPU Belt
Alfa Laval 9613360000 UNIQUE SSV 25/1 INCH 200 W 0.8/BLASTED EPDM SHUT OFF NC
Eaton Vickers (Danfoss) 76024B5H10 Filter Element
Bühler 61-0 WW Nivotemp
American Industrial AB-2008-SP Heat Exchanger
JUMO flowTRANS MAG H01
Air Dimensions R221 Extended Head Dia-Vac® Pump Double Head Hazardous Area
Grundfos CRN 64-7 S-P-A-E-HQQE Multi Stage Pump
T-T Electric LAK 6400C DC Motor
Hengstler AC58/0812ES.41PGA-A1-F Absolute Encoder
Revere 5103-B10-50K-60P1 Double-Ended Beam Load Cell
Tempco CAST-IN CROSS HEAD DIE HEATERS
Exheat HB HB Rod-Type Industrial Immersion Heaters
Knf NMP015KPDC-S Micro Diaphragm Gas Pump
SKF 6000-2Z/C3 Bearing
Epe Italiana BS20MP360A9G5-CP15 Accumulator Safety Block
Beka CS1,5 CS3 MULTI LINE OIL PUMPS
Hengesbach KERAMESS KS200 superior precision pressure and level transmitter