im-tek.com

Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco TDA463-1/2-1M-15/46 Pressure Sensors
Dynisco 462010136 Pressure Sensor
Dynisco MDT462F-1/2-2C-15/46-B171 Melt Pressure Transmitters
Dynisco PT291- S4-7K-4,8 /3.2R-B906. 6K Pressure Sensors
Dynisco SPX2243-N-A25-B-21-CE-FF-C-CE-ZZ Pressure Sensors
Dynisco 2291NA48K11BUTTACAZZ Pressure Sensors
Dynisco TPT463E-10M-6/18-B628 Pressure Sensors
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT4624-5M-6/18-B628 Pressure Sensors
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco MDT462F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco DYMT-S-M18-PT100/4-15-15-G Melt Temperature Probe
Dynisco SPX2291SA56K09BSTTCCAZZ Pressure Sensors
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco UPR90031100100 Process Indicator
Dynisco SPX4622-S-A-00-B-21-DP-DD-A-AA-ZZ Pressure Sensors
Aerzen 165149000 Spacer Ring
Santerno Solardrive Plus Solar Pumping
Brinkmann STA1303/370 Immersion Pump
Air Control ISO 3320 HV Series Hydraulic Cylinders
KSB MCPK080-050-250 FF NP2 A Pump
Dropsa 2452012-1000 Pump
MBS MLD 100 7 22 1 1000 Mixflo Multitube Demontable Heat Exchanger
Dropsa 1A-0675017 02 Mod. Ass-1cc Dmm 6 Bsp Outputs
Vogel MKU1-13AD02000 924 Single Line Pump
Italvibras CDX 15/2000-G/D 601358 Explosion Proof-electric Vibrator
Adalet XCE-142213 Explosion Proof Control Enclosures
Hengstler AD36/1217AF.0CSCB Absolute Encoder
Sensitron S2624ME-LD Gas Detector
Metalwork 6169010U V3V 400 1 KEY-OPERATED
Habasit NAB-10ESBV 13 Light Conveyor Belt
Eaton Vickers (Danfoss) F3-CVI-25-D20-L-50 Insert
Stahl 8220/5-SM-ES5,5kW400V-T DOL Motor Starters, Star Delta Starter, Soft Starter
Felm FAA3-355F4-06P Motor
PCM HYCARE™ 40HY6 Cavity Pump
Stahl 8146/5072 Control Box
Samson 1011518 Converter
FSG SL 3005 Series Rope Length Transmitter
Atos E-ASB-USB/BTH Connection Adapter Cable
Aoip ISOPALM 200 Cable Fault Locator