im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco SPX4222-S-A-00-B-13-EZ-DD-C-AA-ZZ-Z017 Pressure Sensors
Dynisco MDA460-1M-15 Pressure Sensors
Dynisco PT4624-15-M-6/18 Pressure Sensors
Dynisco MDT462F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco MDT420CAN-/2-7C-15-HA51 Melt Pressure Transmitters
Dynisco UPR900-3-1-0-0-0-0-0-0 Process Indicator
Dynisco PT4624-10M-6/18-SIL2 Pressure Sensors
Dynisco MDT463H-1/2-5C-15/46 Pressure Sensors
Dynisco PT 415D-5M-6-B314-B173 Pressure Sensors
Dynisco TPT4634-5M-6/18 Pressure Sensors
Dynisco PT291-6K4,8 B906 Pressure Sensors
Dynisco ATC990-411111000 Process Controller
Dynisco PT303-5C Pressure Sensors
Dynisco PT462E-10M-6/18-B220 Pressure Sensors
Dynisco TDT432F-1/2-3,5C-15/46-D69/285-SIL2 Pressure Sensors
Dynisco TDT463L-1/2-7C-15/46 Pressure Sensors
Dynisco TDT432F-1/2-5C-46/46-S137-SIL2 Pressure Sensors
Dynisco MDA462-1/2-7C-15/46 Pressure Sensors
KWD TK-N-A 900 - 65 H7 - 70 H7 x 140 - KWN 29000 Coupling
FIP Italy SSELV Series DN 10÷50 Easyfit Ball Check Valve
Gemü Gemü 615 12D 1125211/N Diaphragm Valve
Globe VA1PFG02_20 Vane Motor
Gefran LT-M-0800-P 0000X000N00 Potentiometer
Gefran LT-F-0175-S 0000X000B00 Potentiometer
Westcode N1817QL080 Phase Control Thyristors-Capsule
Gefran LT-F-0225-S L000X000X00 Potentiometer
Aignep 50200N TEE MALE ADAPTOR (TAPER) - CENTRE LEG
Alfa Laval 9612628458 LKB F 101,6/4
Conductix Wampfler L-Line 0364 Series I-Beam Cable Trolleys
Landefeld Straight screw in connections, G-threads / R-threads
Alfa Laval TE67G411301630 TT: ´-20 to 150 °C 6mm tip,30 cm Clamp 1½",M12 Plug,N/A
Gestra BB 25C PN 25 check valve
Italvibras MVSI 10/6600-S02 602136 Electric Vibrator
Roemheld H4.306 Series Concentric Clamping Element
Gefran LT-F-0130-P 0000X000B0N Potentiometer
Hengstler RI58-O/10000AK.46KC Encoder
Amot JSF 1E It Flow Switch
Alfa Laval 9612628573 LKB-2 DN40 DIN W/W EPDM 316L KIT ACT LKLA-T Ø85 NC 6MM
Faulhaber AM1020SB004501 Stepper Motor
Valco SAFE POT Safety Barrier
Fybroc 3x4x10 Series 5500 Vertical Sump Pump
Gefran LT-H-0200-P 0000X000X00 Potentiometer