im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S12-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S12-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S12-NFL-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDT462F-1/2-7C-15/46 Melt Pressure Transmitters
Dynisco MDA462-1/2-5C-15/46 Pressure Sensors
Dynisco MDT 422F-1/2-3.5C-15/46-B171-B173-SIL2 Melt Pressure Transmitters
Dynisco MDT462H-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco TDA463-1/2-1M-15/46 Pressure Sensors
Dynisco MDT420F-1/2-1M-15-SIL2 Melt Pressure Transmitters
Dynisco MDT 422F-M18-35-15/46-A Melt Pressure Transmitters
Dynisco PT291-6K4,8 B906 Pressure Sensors
Dynisco MDT462F-1/2-1C-15/46 Melt Pressure Transmitters
Dynisco PT4624-3M-6/18-B171-A Pressure Sensors
Dynisco IDA354-3,5C-10V-S78B Pressure Transmitters
Dynisco PT482-1/2-10M-6/18-B379 Pressure Sensors
Dynisco SPX 2291SA56K21BSMMACAZZ Pressure Sensors
Dynisco PT415D-5M-6-B314-B173 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensor
Dynisco PT4604-3M-12-A Pressure Sensors
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco DYMT-S-1/2-J20-15-G Melt Temperature Probe
Habasit XVT-2195 Belt
Vogel MKF1-11AC00000 428 Single Line Pump
Eaton Vickers (Danfoss) 45V42A-86B20-282H Pump
Enerpac XC2204ME Cordless Hydraulic Pump
Emotron FDU48-205-20 Drive
SKF 6216-2RS1 Bearing
SETTIMA SMAPI API 676 Pumps
Vulcanic 2115-26 Screw Plug Immersion Heater
Adalet CN4X6-241608 CN Series Control Enclosures
American Industrial AA-1260-TP Heat Exchanger
Sumitomo ASTERO® Gearmotor
Oiles OILES Toughmet D includes bearings
HFB GOS 618 Plummer Block Housing
Aron QC3-3-03-K1-R-30 Valve
Alfa Laval 8010001808 UNIQUE RV-P NO 51MM KV25 EPDM VALVE
Apv TPM +1 Batch Powder Mixers
Edur NUB32-160/C150L-2900 Single Stage Close-Coupled Pump
Leine Linde 1000 Extreme in every way. Handles most things
KSB UPHA 293/07+HBCN 303 6.0 SQMM S.D. Pump
HFB BTL 3160 K Two Bearing House
T-T Electric LAK 4180AA DC Motor
Atlas Copco 2202 9249 01 (SET 2X) XPZ L=1 V-belt
Schorch BD7 180L Three-phase-motor
Martens GTF 102-Ex ATEX Industrial Probe