im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S12-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S12-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S12-NFL-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDT422F-1/2-2C-46/46-SIL2 Melt Pressure Transmitters
Dynisco DYMT-F-1/2-PT100/4-0-15-G-2M Melt Temperature Probe
Dynisco MDA462-1/2-7C-15/46 Pressure Sensors
Dynisco VERT-MA4-MM1-NDC-BAR-R23-UNF-6PN-SO6-F18-NTR-NCC Melt Pressure Sensor
Dynisco SPX 4222 N-A-00-B-17-CE-DD-A-AF-ZZ-GC8 Pressure Sensors
Dynisco 4622NA00P24CEDDAAFZZGC7 Pressure Sensor
Dynisco PT462E-7CB-6/18 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/91-SIL2 Melt Pressure Transmitters
Dynisco DYMT-S-1/2-PT100/4-15-15-G-1M-F13 Melt Temperature Probe
Dynisco PT4624-10M-6/18-SIL2 Pressure Sensors
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco ATC990-401111000 Process Controller
Dynisco ECHO-MV3-MPA-R21-UNF-HIR-S06-F18-NTR Melt Pressure Transducers
Dynisco PT4624-5M-6/18-B628 Pressure Sensors
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT291-10K-4,8 / 60.B906 Pressure Sensors
Dynisco TPT463E-1/2-10M-6/18 Pressure Sensors
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Knf NF 1.600 Series Diaphragm Liquid Pump
MBS MLW 88 7 18 1 1500 Sanitary Mixflo Multitube
Böhmer KSF R 025.020 Ball Valve
Hengstler AC58/1212EK.42I2I Absolute Encoder
Alfa Laval 9613359621 VALVE UNIQUE RV-ST 38/1.5 200 WELD NC REGULATING 0.8/BLASTED KV-10 EPDM
Greisinger GMH 1170 Precision Quick Response Thermometer
Adalet CN4X6-363020 CN Series Control Enclosures
Gefran LT-F-0450-P 0000X000X0N Potentiometer
Eurotherm 2721120T 0.3-1.5 Bar 4 Pin Pressure Switch Eurotherm 2721120T 0.3-1.5 Bar 4 Pin Pressure Switch
Pall UR629CF6420ZA Duplex Filter
Hengstler RI59-O/500EQ.7AIB Encoder
KSB UPF 80/05+UMAI 150 Pump
Scherzinger 5030-130-DM-55-4-Exe Stainless Steel Gear Pumps 5030
Siemens 6ES7516-3UN00-0AB0 Simatic S7-1500T CPU
Bühler WW 6 Water Alarm Unit WW
Greisinger GTF1200 Immersion Probe
Faulhaber 2657W024CXR DC-Micromotor
Parker 15P205QHBE2KS122 Duplex Filter
Vulcanic 2119-22 Screw Plug Immersion Heater
Ifm O5E200 Through-beam sensor receiver
Vulcanic 2389-79 Flange Immersion Heater
Adalet XHVX-242410 Flameproof High Voltage Enclosures
Tsurumi KW Series 3-phase / 50Hz Sewage Treatment Equipment
Woerner VPB-B Progressive distributor