im-tek.com

Dynisco ECHO-MV3-MPA Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDA462-M18-3,5C-15/46 Pressure Sensors
Dynisco PT160-5C Pressure Sensors
Dynisco UPR900-2-1-0-1-0-0-0-0 Process Indicator
Dynisco TPT463L-1/2-10M-6/18 Pressure Sensors
Dynisco PT462E-3.5CB-6/18 Pressure Sensors
Dynisco MDT422F-1/2-3,5C-15/46 Melt Pressure Transmitters
Dynisco MDT 462F-1/2-3,5C-32/46A Melt Pressure Transmitters
Dynisco MDA462-1/2-5C-15/46-B171 Pressure Sensors
Dynisco TPT484-5M-6/18-B379 Pressure Sensors
Dynisco EPR3-1.5M-6-TC-M561 Melt Pressure Sensors
Dynisco TPT463E-10M-6/18-B628 Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-A Melt Pressure Transmitters
Dynisco TPT4634-3M-6/18-SIL2 Pressure Sensors
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco DYMT-S-1/2-J-10-30-G-0,7M-F13 Melt Temperature Probe
Dynisco PT 415D-5M-6-B314-B173 Pressure Sensors
Dynisco SPX4222-N-A-00-B-21 Pressure Sensors
KSB UPF 80/25+UMAG150-21/21 4.0 SQMM S.D. Pump
Faggiolati G210R6D4-J7AA2 Pump
Faggiolati G211R6T2-L8AA6 Pump
Mp Filtri EGE2 Coupling Rubber
VIMARC AX 75-8-RVS Vibrator motors
Moog G761-3039B S63JOGA4VPL Valve
Scherzinger 5040-130-B-DM-150-6-Exe Hastelloy (R) Gear Pumps 5040
Faulhaber DM40100R2R094000 Stepper Motor
Nippon 1508 Procon Pump (1.4MPa)
Faggiolati G418R3V2-S100AA2 Pump
Emod EeDA 100L/6 Motor
Eaton RV1 8 S0 50 Modular Control
KSB MCPK100-065-160 CC NP2 A Pump
Beka EFP-1 (DC) SPECIAL PUMPS FOR BARREL
Janitza 5222063 Energy Measuring Device
Vulcanic 2381-05 Flange Immersion Heater
ETP II 20 / 25-30 Clamping Bush
Chiaravalli 91304505 Pulley
Volta FHK Flange Heater
Negele MPI-200 Programming Adapter
KSB BPD262/06A+UMAISOL 150-4/22 A Pump
Eurotherm EPC3016/P1/VH/R2/R2/XX/XX/XX/CE/XX/TK/XXX/ST/XXXXX/XXXXXX/XX/X/X/X/X/X/X/X/X/X/X/X/ Controller Eurotherm EPC3016/P1/VH/R2/R2/XX/XX/XX/CE/XX/TK/XXX/ST/XXXXX/XXXXXX/XX/X/X/X/X/X/X/X/X/X/X/X/ Controller
Voith IPV3/-8/ 101 Internal Gear Pump
Eurotherm 2404/CC/VH/H7/XX/W5/XX/XX/XX/XX/ENG/XXXXX/XXXXXX/ K/0/1200/C/XX/XX/XX/XX/XX/XX/XX Process Controller