im-tek.com

Dynisco ECHO-MV3-MPA Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDT462F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco ATC880-0-3-3 Process Controller
Dynisco MDT 462F-1/2-3,5C-15/91-A Melt Pressure Transmitters
Dynisco MDT422F-1/2-3,5C-23/46-A Melt Pressure Transmitters
Dynisco ATC990411101000 Process Controller
Dynisco TPT463E-10M-6/18 Pressure Sensors
Dynisco DYMT-S-1/2-J20-15-G Melt Temperature Probe
Dynisco FMMX-5CK-6/30 Melt Monitor Alarm
Dynisco SPX4222-N-A-00-B-21 Pressure Sensors
Dynisco TPT4634-7.5M-6/18 Pressure Sensors
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco MDT422F-1 / 2-3.5C-15/99-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-M18-3,5C-50/46-A Melt Pressure Transmitters
Dynisco DYMT-F-1/2-PT100/3-0-32-G Melt Temperature Probe
Dynisco PT160-4M Pressure Sensors
Dynisco TPT4636-M14-50MPA-6/18-TC6 Pressure Sensors
Dynisco ATC990-4-0-1-1-0-1-0-0-0 Process Controller
Dynisco DYMT-S-1/2-J-5-15-G Melt Temperature Probe
Elmo Rietschle L-BV2 Liquid Ring Compressor
Nuovafima MGS32 DN125
Habasit APH150HBR/BR Heavy Conveyor Belt
Stauff 1910000486 Filter Element Sgb-120-03-B
KSB Multi Eco 34D 3~ 230/400V IE2 Pump
Greisinger APG-2 Housing for Surface Mounting
Nuovafima MN17 DN150
Gefran LT-M-1050-P L000X000X00 Potentiometer
MBS MLW 114 10 18 1 2000 Sanitary Mixflo Multitube
Anderson Greenwood MT Differential Pressure Manifold
Vulcanic 2118-15 Screw Plug Immersion Heater
Gefran WPG-A-W-0300-N 0000X000X00X0XX Magnetostrictives
Gefran PC-H-0950 0000X000D0N Potentiometer
Vulcanic 2048-17 Screw Plug Immersion Heater
YTC YT-205 Air Filter Regulator
Gefran LT-F-0700-S 0000X000A0N Potentiometer
Scherzinger 3030-045-DM-09-6-Exe Stainless Steel Gear Pumps 3030
Ex-tech XBW4BA21 Push Button
Hengstler AC58/1212EK.42CLD Absolute Encoder
CMO Serie R Check Valve
Gefran LT-M-0800-S L000X000N00 Potentiometer
Amg Pesch DAF-42 Double-Piston Quarter Turn Actuator
Edur NU1001G175L-2900 Multi-Stage Centrifugal Pump
Megger MJOLNER600 Micro-ohmmeter