im-tek.com

Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

• 2 year warranty and 60 years of Dynisco industry experience• Accuracy better than ±0.5%• TiAlN diaphragm coating is standard• mV/V, 0-10VDC, or mA outputs available• Integral temperature sensor option• Available in configurations that fit most extruder applications• 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability• Alternative fill model availableOperating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco 1392-1-3 Temperature Indicator
Dynisco MDT462F-1/2-2C-15/46 Melt Pressure Transmitters
Dynisco TPT4634-3M-6/18-SIL2 Pressure Sensors
Dynisco MDA460-1/2-5C-15 Pressure Sensors
Dynisco MDT422F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco PT4624-15M-6/18-GC7 Pressure Sensors
Dynisco MDT 462F-1/2-3,5C-15/46-T80 Melt Pressure Transmitters
Dynisco MDT462F-1/2-3.5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-1/2-5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco PT4626-1/2-35MPA-6/18 Pressure Sensors
Dynisco MDT420CAN-M18-1M-15-MST Melt Pressure Transmitters
Dynisco TPT463E-1/2-10M-6/18 Pressure Sensors
Dynisco MDA462-1/2-3,5C-32/46 Pressure Sensors
Dynisco TPT463E-35MPA-6/18 Pressure Sensors
Dynisco PT462E-3M-6/18 Pressure Sensors
Dynisco PT4604-3M-12-A Pressure Sensors
Dynisco MDT462H-1/2-7C-15/46-B106-D85 Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Kirchgaesser MID-EX-E with CANopen Electromagnetic Small Flow Meter
Sensitron S4004TO Sensor Head
American Industrial URCN-1236 Heat Exchanger
Aoip IND 43 Safety ohmmeter on Pyrotechnical Elements
Skf CR47583 Shaft Seal
Magnaloy M100M2808 Bore
Eaton 25V21A1C22R V Series Single Vane Pump Cartric
JVM JVC 106-35 Unbalance Motor
Faulhaber 17/1 91:1 Planetary Gearhead
SKF PSMF 030604 A51 Bushing
Alfa Laval 9613407311 LKB 101,6/4
Pall HZ4751E24TW1 Duplex Filter
Festo DSR-25-180-P Rotary Actuator Festo DSR-25-180-P Rotary Actuator
Nuovafima 1.18.1.A.G AAE5 43M C K06 Gauge
Enerpac RCH302 Hydraulic Cylinder
Alfa Laval LKLA Ø133 14MM DN125 NC 9612271311 Actuator
Bronkhorst M-422-17-00-V In Line Filter
PCM 40I10 Progressive Cavity Pump
Young-Massa LDRS06 Rotary Valve
Jaquet DSF 2215.01 AHV Ex-atex Sensor
VISHAY BLH DXp-40 “Expert” Weight Transmitter
Bedia Typ SPW 003 24 V/12 V DC – 3 A Connector Bayonet Acc. to ISO 15170
Kelvion GBH-HP-DW 500H Brazed Plate Heat Exchangers
Gestra MPA46