im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Dynisco TPT4634-5M-12/18 Pressure Sensors
Dynisco PT462E-1/2-1M-6/18 Pressure Sensors
Dynisco PT482-1/2-15M-6/18 Pressure Sensors
Dynisco IDA354-3.5C-10V-S78B Pressure Transmitters
Dynisco PT4624-15-M-6/18 Pressure Sensors
Dynisco MDT422F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco PT462E-15M-6/18 Pressure Sensors
Dynisco PT4624-1/2-5M-6/18 Pressure Sensors
Dynisco PT4624-5C-6/18 Pressure Sensors
Dynisco MDT462F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco PT462E-M18-7CB-6/189 Pressure Sensors
Dynisco TPT4636-M14-50MPA-6/18-TC6 Pressure Sensors
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco UPR900-4-0-1-1-1-0-0-0 Process Indicator
Dynisco ATC8800230 Process Controller
Dynisco IDA334-1M Pressure Transmitters
Dynisco PT130-3M Pressure Sensors
Wandfluh ADRVdN6H/125 (604.3027) Valve
Santerno SINUS N 0002 2S XIK2 Inverter
Alre JDL-111 Pressure Switch
Holmatro HAHC100H15 Aluminium Hollow Plunger Cylinder
Vulcanic 2206-76 Flange Immersion Heater
Atlas Copco 2901990101 Prev. Maint. Kit C142 Ga75vsd+
Wilkerson M30-C8-000 Coalescing Filter
Stenflex Type SG-11 DN 40 Expansion Joint
Alfa Laval 9612628254 LKB 76/3
Spirax Sarco M70i G ISO Ball Valve
SKF W 604 R Deep Groove Ball Bearings
JVM JVC 274-380 Unbalance Motor
Brevini S6CV P 128 125 125 ME 11 BF DX HER 24 08 23 35 35 AF PC 300 M8 G2 XX XXX XX Pump
Atlas Copco GA30P A 7.5 Compressor
Gemü Gemü 600 8M5A Diaphragm Valve
ETP HS 1
Scherzinger 5040-130-ZK80-160 Hastelloy (R) Gear Pumps 5040
FIP Italy VKRNV Series DN 10÷50 DUAL BLOCK® Regulating Ball Valve
Hansa-TMP SFIM3003100 Flanges and Pipe Fitting
Infineon BSM150GB120DN2F Module
Kant Pressure switch with make contact type 810
Asm KAB-0,2M-TSSI2 Adapter
Parker DF20353015NVNHD651 Duplex Filter
ACL SRL 306 NO 3/2 Direct Acting NO