im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDT462F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco SPX4622-S-A-00-B-21-DP-DD-A-AA-ZZ Pressure Sensors
Dynisco TPT4634-5M-6/18 Pressure Sensors
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-F30-NTR Melt Pressure Transducers
Dynisco 224200001317 Pressure Sensors
Dynisco PT4624-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco PT462F-1/2-10M-6/18 Pressure Sensors
Dynisco UPR900-2-1-0-1-0-0-0-0 Process Indicator
Dynisco DYMT-S-1/2-J-10-30-G-0,7M-F13 Melt Temperature Probe
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco MDT462F-M18-7C-15/46-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-1/2-2C-15/46 Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Dynisco SPX2291SA56K11BSTTCCCZZ Pressure Sensors
Dynisco MDA-460-1/2-1M-15 Pressure Sensors
Dynisco MDT420F-1/2-1M-15-SIL2 Melt Pressure Transmitters
Dynisco PT160A-4M-H88 Pressure Sensors
Dynisco PT-242FM-20MPA-6 Pressure Sensors
Mahle Pi 241005/1C/N-057 70535419 Duplex Filter
Kelvion GBS 700L/M Brazed Plate Heat Exchangers
Faggiolati G618R3C2-T102AA2 Pump
Vogel 342-8VS-15000-ZZ Single-line - Piston Metering Device
Alfa Laval TE67EA21111220 PT: 0 to 40 bar 0,1% FS Clamp 2",gland M20,N/A
Heidenhain ECN 413 2048 01 -58 K 1,00 02 70C14 64 01 .. .. D EnDat01 37 01 Rotary Encoder
Elwa 46152WR-V Flowheater
Eurotherm EPACK-3PH/40A/24V/V2/TCP Thyristor Eurotherm EPACK-3PH/40A/24V/V2/TCP Thyristor
Holmatro HAHC100H15 Aluminium Hollow Plunger Cylinder
Vulcanic 2115-18 Screw Plug Immersion Heater
Faulhaber 22/7 94:1 Planetary Gearhead
Conductix Wampfler UK-310850B Joint Cover
Asco Rubber For 113-699-009 Diaphragm
Valco LINEAR – LCM – V-F Continuous Level Meter
Hansa-TMP KF 200 Axial Piston Motors
Gamak AGM2E 132 M 6b Motor
Gefran WRP-A-B-0500-E-1-1KC 0000XXXXS00M0XX Sensor
Goldammer TRW-NR25-II-T40Ö-MS-24V-200-3+PE Temperature Monitor
Moog H40JOFM5VBQ Servo Valve
Italvibras MVSI 15/6000E-S02 6E1447 Increased Safety Electric Vibrator
MBS MLW 60 3 18 1 6000 Sanitary Mixflo Multitube
Eurotherm 2404/P4/Vh/H7/S5/Pe/Xx/Xx/Xx/Xx/Eng/Xxxxx/Xxxxxx Controller Eurotherm 2404/P4/Vh/H7/S5/Pe/Xx/Xx/Xx/Xx/Eng/Xxxxx/Xxxxxx Controller
Fortress Interlocks MSSR Mini Solenoid Controlled Key Switch in Enclosure
Scherzinger 4050-450-DM-25-4-Exe Titanium Gear Pumps 4050