im-tek.com

Dynisco ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco 462H0002 Pressure Sensor
Dynisco PT492-35MPA-15/46 Pressure Sensors
Dynisco PT4624-3M-6/18-B171-A Pressure Sensors
Dynisco PT-242FM-50 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco PT462E-10M-6/18 Pressure Sensors
Dynisco IDA-334-1 M-10V Pressure Transmitters
Dynisco PT462F-1/2-10M-6/18 Pressure Sensors
Dynisco MDA-460-1/2-1M-15 Pressure Sensors
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco MDT422T-1/2-3,5C-15/46A Melt Pressure Transmitters
Dynisco PT4626-10M-6/18 Pressure Sensors
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDT462F-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco PT462E-1/2-1M-6/18 Pressure Sensors
Dynisco TPT4634-35MPA-12/18-SIL2 Pressure Sensors
Dynisco MDT 462F-1/2-3,5C-15/46-T80-SIL2 Melt Pressure Transmitters
Kadant 9942013/0001 SNX Rotary Joint
Stahl 8146/5-V27-201-11502-21-1 Load Disconnect and Manual Transfer Switch
Beka FHX-2 MULTI-LINE GREASE AND OIL PUMPS
Ziehl FE080-SDA.6N Fan
Micro Detectors CF/CB3-20 Photoelectric Sensor
Goldammer NTR 85-SR30-T1-A-FE-L370-01-L1/250/S-T10Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Atos PFE-41070/7DW 20 Valve
SKF S7204 CD/P4A Angular Contact Ball Bearing
American Industrial EAB-1603 Heat Exchanger
SKF 23948 CC/W33 Bearing
Scherzinger 4030-450-B-ZK71-140 Stainless Steel Gear Pumps 4030
Intorq 27940 BFK 458-14 Hub
Stauff Hks-M6X45-W55 Nuts
Hansa-TMP SFIM3001012 Flanges and Pipe Fitting
Habasit TT23/GP White TPU Belt
Air Dimensions B101 B-Series Dia-Vac® Pump Single Head
Atlas Copco 2906904500 Oil Demistor Service Kit
SKF SYJ 514 Bearing
Bernard Controls BCI0073482I Motor
Goldammer MA-GB-311 NR 6/32 – MA Level-temperature regulator with resistance measuring chain and restance thermometer, output 4-20mA
Eaton Vickers (Danfoss) 760268 4CT06A20UB Check Valve
Tsurumi 80UYZ Series 3-PHASE / 50HZ Sewage Pumps
Meister KM-335-3000 Flowmeter
Mahle Pi 47016-015 70304341 Duplex Filter