im-tek.com

Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco MDT422F-1/2-3.5C-32/46-SIL2 Melt Pressure Transmitters
Dynisco 2242NA00K23CEFFCACAAB300 Pressure Sensors
Dynisco TPT432A-3M-6/18 Pressure Sensors
Dynisco ATC990-4-0-1-1-1-1-0-0-0 Process Controller
Dynisco MDT 422F-M18-35-15/46-A Melt Pressure Transmitters
Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDT462F-1/2-1C-15/46-SIL2 Melt Pressure Transmitters
Dynisco UPR900-20000000 Process Indicator
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco PT4624-1/2-35MPA-6/18 Pressure Sensors
Dynisco ATC990-4-1-1-1-0-1-0-0-0 Process Controller
Dynisco UPR90031100100 Process Indicator
Dynisco PT4624-5M-6/18-SIL2 Pressure Sensors
Dynisco FMMX-5CK-6/30 Melt Monitor Alarm
Dynisco PT4626-1/2-35MPA-6/18 Pressure Sensors
Dynisco UPR900-2-0-0-0-0-0-0-0 Process Indicator
Dynisco DYMT-F-M18-PT100/4-0-15-G Melt Temperature Probe
Dynisco TDT463F-1/2-3,5C-15/46-A Pressure Sensors
Aignep 241AC STEEL MALE PLUG
Amg Pesch M215 Limit Switch Box
Starline 225SGS-F/BSP-P Standard Ball Valve
Atlas Copco 2901300109 Filter Kit Pd/ Pdp 310+
Vulcanic 2006-42 Flange Immersion Heater
MBS MLD 88 4 16 1 3000 Mixflo Multitube Demontable Heat Exchanger
Eltra EH80P1024Z8/24L10X3 PR2 Encoder
Santerno IM0141782 Inductor
Felm FAA3-500F6-10P Motor
Scherzinger 5030-210-DM-110-6-Exe Stainless Steel Gear Pumps 5030
Alfa Laval 9612628494 LKB-2 DN25 DIN M/W EPDM 304L KIT ACT LKLA-T Ø85 NC 6MM
Atlas Copco 1617 5050 53 Rotor
SKF W 605-2RS1 Deep Groove Ball Bearings
Eaton 02-341561 PVQ20-B2R-SS1S-21-C21-12 Pump
Senseca USB3100N-GE Interface Converter
Bernard Controls AQ0080TA055S3300EBM Actuator
Grundfos NK 32-160/154 AA1F2AESBAQEDW3 Pump
HFB SSNI 509 Plummer Block Housing
Scherzinger 4040-280-DM-25-8-Exe Hastelloy (R) Gear Pumps 4040
Eltra EH63D500S8/24P10S3MR.L Encoder
Gefran LT-M-0400-S 0000 X 000 X0C Rectilinear Displacement Transducer
Meister SPKR-20 Paddle Flow Monitor For Liquids
SKF FRB 5.5/72 Ring
KSB MCPK050-032-2501GG NP2 A Pump