Nom du Produit: Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM
Marque: Bartec
Code Produit: 17-9Z62-0002
Mots-clés: Bartec
17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM
COUPLING ELEMENT
Bartec 17-9Z62-0002 RESISTIVE COUPLING 1KOHM-10KOHM
Bartec RESISTIVE COUPLING ELEMENT
17-9Z62-0002 COUPLING ELEMENT
17-9Z62-0002 COUPLING
RESISTIVE
Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT
Bartec 17-9Z62-0002 RESISTIVE
17-9Z62-0002 RESISTIVE ELEMENT 1KOHM-10KOHM
Bartec ELEMENT
Bartec 17-9Z62-0002 COUPLING ELEMENT
17-9Z62-0002 RESISTIVE COUPLING ELEMENT
Bartec 17-9Z62-0002 RESISTIVE ELEMENT
Bartec RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM
17-9Z62-0002 COUPLING ELEMENT 1KOHM-10KOHM
1KOHM-10KOHM
17-9Z62-0002 1KOHM-10KOHM
RESISTIVE COUPLING 1KOHM-10KOHM
RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM
Êtes-vous intéressé par le produit Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM du fabricant Bartec avec le code 17-9Z62-0002? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM de notre équipe de support en direct maintenant!
DescriptionThe resistive coupling element is used to monitor open and short circuits in isolator amplifier circuits controlled by mechanical contacts. The coupling element is installed directly to the control contact or inside its terminal box.FunctionNumerous isolator amplifiers can monitor the connected sensor line for open or short circuit conditions thanks to the employment of electronic proximity switches to which current can be applied in both damped and undamped status (DIN EN 60947-5-6). Current values outside the specified range are identified as open or short circuits. If simple mechanical contacts are used, it is not possible to identify a short circuit.Neither can be distinguished between open circuit and open contact. This problem can be solved by installing a resistor combination at the end of the sensor line immediately before the switch. This combination provides a closed-circuit current even when the contacts is open. At closed contact it restricts the current to a value which lies clearly below the response threhold for short circuit.Four states can be detected:open circuit (broken cable)open switchclosed switchshort circuitThe resistive coupling element can be used with all isolator amplifiers featuring open and short circuit monitoring, e. g. BARTEC, CEAG, Hartmann & Braun, Pepperl + FuchsTechnical data *Dimensionssee data sheetStorage temperature-40 °C to +70 °CVoltagemax. DC 20 VPower2.4 W at T5Resistance1 k?/0.6 W10 k?/0.6 WConnectionTerminals: 1,5 mm²Connection cable: 0,75 mm²*Refer to the documentation for more detailed information