im-tek.com

Biolab Miniflash Touch Flash Point Analyzer

Biolab

Product Code: Miniflash Touch
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab Miniflash Touch Flash Point Analyzer

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoints of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving the test results. Its continuously closed cup design and small sample volume of only 1-2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste. The fast thermoelectric cooling at the end of a test and the fast and easy handling of the instrument save expensive labor time. The full color touch-screen of the MINIFLASH TOUCH runs on Microsoft® Windows® software and features an intuitive menu navigation that requires no training for flashpoint testing. Along with its convenient touch screen design, the MINIFLASH TOUCH offers an extended temperature range from 0 to 400°C, hassle-free communication with USB, Ethernet, LIMS and PCs and nearly unlimited storage capacity for programs and results. MINIFLASH determines the flash point according to ASTM D6450 and according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A” as concluded during the last Round Robin. Furthermore, test results are equivalent to other well known standards such as Abel and TAG, and thanks to its unique design MINIFLASH can be used for more difficult applications such as flash-point testing of contaminated samples like diesel fuel in lube oil or gasoline in diesel fuel and for biodiesel testing. The new MINIFLASH TOUCH analyzer also includes improved methods for simulation of EN ISO 3679 and EN ISO 3680. Due to true portability and rugged housing, the MINIFLASH TOUCH is also the perfect solution for mobile labs and military applications. Features Flashpoint according to ASTM D6450 (Flash-Point by Continuously Closed Cup) and ASTM D7094 (Flash-Point by Modified Continuously Closed Cup) FLASHPOINT COMMITTEE STATEMENT: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A.”), equivalent EN ISO 2719, excellent correlation to ASTM D56, ISO13736, IP170 New methods for EN ISO 3679 and EN ISO 3680 simulation Dilution Flashpoint Testing Go / No Go Flashpoint Testing Fast Screening Methods Automatic ignition cleaning method Maximum safety through Grabner continuously closed cup method (Ignition Protection Technology™) 1-2 ml sample size * No Open Flame, no offensive vapors in the lab * Highest accuracy (see precision statement) Extended temperature range: 0 to 400°C with external cooling (MINIFLASH FLPH TOUCH) Fully remote operable * Big, color touch-screen for convenient, intuitive menu navigation Touch Screen Runs on Microsoft® Windows®: Full integration with network, LIMS and PC Hassle-free communication and data transfer via USB and Ethernet USB printer support Good Laboratory Practice: User Access Control Portable for Mobile and Field Use (car battery connector) Worldwide standard method for the flavors and fragrances industry Approved for the ASTM specifications of recycled fuel and biodiesel Short measuring time (depends on sample type) due to small sample volume of 1-2 ml Combustion Analysis™ Excellent thermoelectric heating and cooling regulation through Peltier Protection Technology™ Specifications MINIFLASH FLP TOUCH: 0 to 200 C (32 to 390 F) MINIFLASH FLPH TOUCH: 0 to 400 C (32 to 750 F) MINIFLASH FLA/FLAH: With 8 sample capability autosampler Power Requirements: 100/110/230 V AC, 50/60 Hz, 150 W

Recommended Products For Biolab


Biolab M Series Signal Silicon Analyzer
Biolab Phoebe M Series Phosphorus Analyzer
Biolab Filmdist TF 650 Thin-Film Evaporation
Biolab TB 30 LPG Copper Corrosion
Biolab InfraCal 2 Analyzers Measuring Oil In Water & Soil
Biolab Filmdist SP 500 Shorth Path Evaporator
Biolab CoolCheck® 2 Coolant And Diesel Exhaust Fluids (DEF) Analysis System
Biolab MiniLab 53 Oil Analysis System
Biolab PETRA EDXRF Sulfur Analysis System
Biolab PETRODIST 200 Crude Oil Distillation System
Biolab TC16 Copper Corrosion Analyzer
Biolab PETRODIST 300 Crude Oil Distillation System
Biolab PAT940 TAN/TBN Analyzer
Biolab MINIVAP VP Vision Vapor Pressure Tester
Biolab TLC 15 Hydrometer Method Density Meter
Biolab Q6000 FDM Series Fuel Dilution Meter
Biolab Miniflash Touch Flash Point Analyzer
Biolab TLC Series Manuel Cloud And Pour Point Analyzer
Telestar ETH-EX42005-001AB Ethernet Switch
Eltra EH80C2048Z8/24L14-X3MR ENCODER
Taprogge PL230 Cleaning Ball
Hengstler AD36/0013EF.0RSC0 Absolute Encoder
KSB MCPK080-050-250 GB NP2 A Pump
SKF 6205-2Z/C3 Bearing
Gefran F007690 ME1-6-M-B01M-1-4-D 2130X000X00 Sensör
Winsmith CTX Series Double Reduction Helical and Worm Gear Speed Reducer
KSB Amarex-N ~ F 50-220/042 YLG-180 Pump
Apv SV / SVS Butterfly Valve
Hengstler RI58-O/10000EQ.46KQ Encoder
Alfa Laval TE67E211111120 PT: 0 to 1 bar 0,35% FS Clamp 1½",gland M20,N/A
Festo DSBC-32-70-PPVA-N3 Iso Cylinder Festo DSBC-32-70-PPVA-N3 Iso Cylinder
Adler FA1 DN10 FLAT BODY BALL VALVES
Scherzinger 3050-045-DM-12-8-Exe Titanium Gear Pumps 3050
Rotork IQ20/F14/A Actuator
MBS MNW 32 60 0 3000 Sanitary Mixflo Monotube Heat Exchanger
Klueber Paraliq GB 363 Synthetic Grease
Bürkert PACTWARE 227093 Adapter
Edur NUB700G165L-3500 Single Stage Close-Coupled Pump
Moog D661-4550C G15H0AA5VSD2H0 Valve
Stenflex GR-SAE DN 80 PN 16 Rubber Expansion Joint
Grundfos NK 100-400/375 BA1F2AESBAQESW3 Pump
Servomech BSA 63 Mechanical Linear Actuator