im-tek.com

Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

• 2 year warranty and 60 years of Dynisco industry experience• Accuracy better than ±0.5%• TiAlN diaphragm coating is standard• mV/V, 0-10VDC, or mA outputs available• Integral temperature sensor option• Available in configurations that fit most extruder applications• 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability• Alternative fill model availableOperating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco DYMT-S-1/2-J-10-15-G-0,7M-F20 Melt Temperature Probe
Dynisco TDT432F-1/2-3,5C-15/46-D69/285-SIL2 Pressure Sensors
Dynisco MDT462H-1/2-7C-15/46-B106-D85 Melt Pressure Transmitters
Dynisco ATC880-0-3-3 Process Controller
Dynisco 462F0156 Pressure Sensor
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT492-35MPA-15/46 Pressure Sensors
Dynisco SPX2291SA56K11BSTTCCCZZ Pressure Sensors
Dynisco TPT-4634-3M-12/18 Pressure Sensors
Dynisco PT303-2C Pressure Sensors
Dynisco UPR900-3-1-0-0-0-0-0-0 Process Indicator
Dynisco PT4624-5C-6/18 Pressure Sensors
Dynisco MDT462F-1/2-3,5C-15-91-SIL2 Melt Pressure Transmitters
Dynisco MDT422F-1/2-3.5C-15/46-B171-B173-SIL2 Melt Pressure Transmitters
Dynisco FMMH-10M-6/30 Melt Monitor Indicator
Dynisco MDT462F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco ATC 770-0-3-3 Process Controller
Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Koba KMA25-25B Shock Absorber
Kadant 9940002/0001 SX Rotary Joint
Stenflex Type A-1 DN 600 – BL 250 Rubber Expansion Joint
Hansa-TMP PV 6P Electronics and Controls
Sensitron S3025R1234ZE Gas Detector
Bernard Controls 85414090-3410165 Actuator
KSB CORACHROM 150-17/09+UMAI 150CH-4/22 Pump
Satron LUMINA VCK Optical Consistency Transmitter with Kappa - Fiber Length
KSB MCPK125-080-250 FF MP2 A Pump
Mp Filtri MPH2504CDSAG1M25P01 Return Filter
Parker 22PD210QHBPXG162 Duplex Filter
Lammers 1TZ9501-1EB6 Squirrel Cage Motor
Eaton 20-100 A C440B2A100SAX Thermal Relay
Elmo Rietschle L-BV2 Liquid Ring Compressor
Kieselmann 4314 G-G-G Multi-way Butterfly Valve
KSB UPFN 150/04+UMAI150-4/22-DOL Pump
Hansa-TMP XV-0P/0.25 Gear Pumps
Edur CV90/2-1-2900 Multi-Stage Inline Pump
Hoyer 3240901299 IE2 Marine Motor
Kübler 8.5020.0851.1024.0022 Encoder
Pizzato VF L36 Arm
Adalet 243610 Explosionproof / Flameproof Cast Stainless Steel Enclosures
Eaton Vickers (Danfoss) PVH131R13AF30E252008001001AE010A Variable Displacement Piston Pump
Amg Pesch SAF-30-BR16 Pneumatic Actuator