Nom du Produit: Epe Italiana B20EP360G1RP Accumulator Safety Block 24V DC
Marque: Epe Italiana
Code Produit: Epe Italiana B20EP360G1RP BLOCCO DI SICUREZZA ACCUMULATORE 24V DC
Mots-clés: Epe Italiana
Epe Safety Block 24V
Epe Accumulator
B20EP360G1RP Accumulator Safety
Italiana B20EP360G1RP Safety Block 24V DC
Epe Italiana Block
B20EP360G1RP Accumulator DC
Italiana B20EP360G1RP Block
B20EP360G1RP Safety 24V DC
Accumulator 24V DC
B20EP360G1RP Accumulator Block 24V
Italiana B20EP360G1RP Accumulator DC
Epe Italiana B20EP360G1RP Accumulator Safety Block 24V
Epe Italiana B20EP360G1RP Safety
B20EP360G1RP Block DC
B20EP360G1RP Safety
Accumulator Block
Accumulator Safety DC
Accumulator Safety 24V DC
Italiana B20EP360G1RP Accumulator Safety
B20EP360G1RP Accumulator Safety Block DC
Article: B20EP360G1RP
Epe Italiana B20EP360G1RP BLOCCO DI SICUREZZA ACCUMULATORE 24V DC
Êtes-vous intéressé par le produit Epe Italiana B20EP360G1RP Accumulator Safety Block 24V DC du fabricant Epe Italiana avec le code Epe Italiana B20EP360G1RP BLOCCO DI SICUREZZA ACCUMULATORE 24V DC? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Epe Italiana B20EP360G1RP Accumulator Safety Block 24V DC de notre équipe de support en direct maintenant!
The precharge pressure P - In most cases the values 0 recomended in Gas Precharge Pressure - page-3 are valid although, as the pressure and, above all, the velocity of the yield required increase, there is the danger that in each cycle the bladder will knock against the poppet valve. In these cases it is possible to use P = 0.8 to 0.7 P . 0 1 The P /P ratio - Any increase in this, will increase the 2 0 stress the bladder is subjected to in each cycle. The maximum operating pressure P - Any increase in 2 this will subject the bladder to greater stress. Flow rate - Flow rate does not affect bladder working life if values given in Table.2 are not exceeded. When approaching the maximum values, make sure there remains a residual volume of liquid > 10% of the volume V0 in the accumulator, in both loading & unloading conditions. The frequency or number of cycles per day. Installation - The vertical position with gas valve on top is the recommended arrangement. When the position is horizontal the bladder tends to rest and rub against the accumulator body. This could result in quicker wear. The operating temperature - This is one of the factors which most affects the life of the bladder: at very low temperatures the bladder tends to become brittle; as the temperature rises, reaching, or going beyond the limits for the elastomer, the stress the bladder is subjected to increases exponentially, which can lead to fracturing within a short time. It should be remembered that the temperature in the accumulator is in many cases higher than the one of the system, and that it rises with each increase of P , of P /P , 2 2 1 and with the volume of the accumulator (in other words, larger the accumulator, lesser is the capacity to dissipate heat)