Nom du Produit: Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Marque: Gestra
Code Produit: LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Mots-clés: Gestra
LRGT 16-1 G1 PN40 4-20 MA
Gestra 16-1 PN40 PT1000 MA
16-1 G1 4-20 L:300MM
PT1000 4-20
PT1000 4-20 MA L:300MM
LRGT G1 PN40 4-20 MA
Gestra LRGT 16-1 PN40 MA L:300MM
Gestra LRGT G1 PT1000
LRGT 16-1 PN40 PT1000 MA L:300MM
LRGT 16-1 G1 PN40 4-20 L:300MM
Gestra PN40
Gestra LRGT PN40 L:300MM
PT1000 L:300MM
Gestra G1 PN40 PT1000
LRGT 16-1 4-20 MA L:300MM
G1 PN40
LRGT 16-1 G1 MA L:300MM
LRGT 16-1 G1 4-20
LRGT PN40 L:300MM
LRGT G1 MA L:300MM
Conductivity Monitoring LRGT 16-1
Êtes-vous intéressé par le produit Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM du fabricant Gestra avec le code LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM de notre équipe de support en direct maintenant!
Description The compact-design conductivity transmitter LRGT 16-1, LRGT 16-2, LRGT 17-1 consists of a conductivity electrode, a temperature sensor for detecting the fluid temperature and a conductivity transmitter unit incorporated in the terminal box. The conductivity transmitters LRGT 16-1 and LRGT 17-1 work according to the conductometric measuring method using two measuring electrodes and the conductivity transmitter LRGT 16-2 works according to the conductometric measuring method using four measuring electrodes. The equipment measures the electrical conductivity of electrically conductive fluids (TDS = Total Dissolved Solids content) and provides a 4-20 mA measuring current as a function of the detected conductivity value. Conductivity transmitters are used in combination with the following equipment as conductivity limiters and continuous blowdown controllers in steam boilers: Conductivity controller LRR 1-51, LRR 1-53 and industrial controller KS 90-1. Conductivity transmitters can also be used as conductivity monitoring equipment in condensate and feedwater systems. The conductivity transmitters LRGT 16-1, LRGT 17-1 are mainly used in steam boilers with low TDS content, e.g. steam regenerators, high-pressure boilers or condensate tanks. The conductivity transmitter LRGT 16-1 is also approved for feedwater monitoring on ships. The conductivity transmitter LRGT 16-2 is mainly used in industrial boiler plants operating with pressures up to PN 40 and max. admissible conductivities acc. to TRD/EN of 6000 ?S/cm