Nom du Produit: GM International D5096S Relay Output Module
Marque: GM International
Code Produit: D5096S
Mots-clés: GM International
International D5096S Output
International
GM International Output
International Relay Output
International Relay
Relay Module
D5096S Output
International Relay Module
D5096S
International D5096S Relay
GM International D5096S Output Module
GM Output
GM D5096S Relay
GM D5096S Module
D5096S Relay Output Module
D5096S Relay
International Relay Output Module
GM D5096S Output Module
GM International D5096S Relay
GM D5096S Relay Output
Relay Output Module
Êtes-vous intéressé par le produit GM International D5096S Relay Output Module du fabricant GM International avec le code D5096S? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour GM International D5096S Relay Output Module de notre équipe de support en direct maintenant!
DESCRIPTIONThe D5096S is a relay module suitable for the switching of safety related circuits, up to SIL 3 level according to IEC 61508:2010 Ed. 2 for high risk industries.It provides isolation between input and output contacts.A wide compatibility towards different DCS/PLC is guaranteed: driving line pulse testing, executed by DCS/PLC, is permitted by a dedicated internal circuit, to prevent relay and LED flickering.D5096S has 2+2 SPST relay contacts connected in parallel and then in series to avoid spurious trip and to increase availability (see function diagram).High availability SIL 3 Safety Function for NE load or F&G / ND load is available.Load is isolated from supply on both polarities: +/AC, -/AC.Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area or in Zone 2.FEATURES• Systematic capability SIL 3.• Installation in Zone 2.• Compatible with DCS/PLC pulse testing.• Line and Load short/open circuit detection.• Presence of load voltage monitoring.• The fault in the field is directly mirrored to the PLC DO.• 5 A high availability to avoid spurious trip SIL 3 contacts for NE or F&G/ND load.• 6 A inrush current at 24 Vdc / 250 Vac.• Input/Output/Supply isolation.• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system.• Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards.SUPPLY24 Vdc nom (18 to 30 Vdc)CHANNELS1SIL LEVELSIL 3SERIESD5000