Nom du Produit: Greisinger GCO100 Compact CO-Measuring Device
Marque: Greisinger
Code Produit: GCO100
Mots-clés: Greisinger
Greisinger GCO100 CO-Measuring
Greisinger CO-Measuring Device
GCO100 Compact
Compact Device
GCO100 Compact CO-Measuring
Greisinger GCO100
GCO100
Compact CO-Measuring
Device
Greisinger CO-Measuring
Greisinger GCO100 Compact Device
Greisinger GCO100 CO-Measuring Device
Compact
Greisinger Compact Device
Greisinger GCO100 Compact CO-Measuring
Greisinger Compact CO-Measuring
Greisinger GCO100 Compact CO-Measuring Device
Greisinger GCO100 Compact
GCO100 Compact CO-Measuring Device
Article: 600062
Compact CO-Measuring Device
Êtes-vous intéressé par le produit Greisinger GCO100 Compact CO-Measuring Device du fabricant Greisinger avec le code GCO100? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Greisinger GCO100 Compact CO-Measuring Device de notre équipe de support en direct maintenant!
CO-measuring device with alarmHIGHLIGHTS:3 display units selectable (ppm, mg / m³ and% CO Hb)Alert at exceeding the maximum concentration at work (MAK / AGW)including interfaceincl. calibration protocolGENERAL:Carbon monoxide (CO) is created by the combustion of carbon. Depending on the effectiveness of the combustion (oxygen supply) and the temperature of the combustion more or less CO gas is created. The gas is inflammable and highly toxic. It is invisible, tasteless and scentless.Even smallest concentrations are dangerous for humans!Therefore a directive exists in Germany, which limits the maximum concentration of CO gas at work (MAK / AGW) to 30 ppm.APPLICATION:Control of the air quality (eg at work place)Checking of heating systems, gas central-heating, fireplaceControl of the air at maintenance work (tunnel, flue gas tract, ...)Detection of CO in the breath of smoker (% CO Hb)Cognition of CO poisoning ie at burnt offering (fire fighters, ...)SPECIFICATIONS:Measuring principle:electrochemical CO measuring cellMeasuring range:0 ... 1000 ppm CO concentrationDisplay ranges:0 ... 1000 ppm CO concentration0 ... 1250 mg / m³ CO concentration0 ... 60.0% CO Hb (estimation via exhaled breath gas)Resolution:1 ppm, 1 mg / m³ or 0.1% CO HbSensor element:integrated in device, measuring inlet at front plate, with inner thread for accessories screw inLife time:> 5 years at proper usage at air suggested test interval: every 6 months (depending on precision requirements)Accuracy: (at range 0 ... 500 ppm)Linearity:<± 5% of measured value ± 1 digitRepeatability:<± 5% of measured value ± 1 digitscope of supply:device, battery, calibration protocol, manual