Nom du Produit: JCT FTC300 Thermal Conductivity Analyser
Marque: JCT
Code Produit: FTC300
Mots-clés: JCT
JCT FTC300 Conductivity Analyser
JCT FTC300 Conductivity Analyser
JCT FTC300 Conductivity
JCT Analyser
JCT Conductivity Analyser
JCT Thermal
JCT Thermal Conductivity Analyser
JCT FTC300 Analyser
JCT FTC300 Thermal Conductivity
FTC300 Thermal Analyser
Thermal Analyser
FTC300 Conductivity Analyser
Conductivity
JCT Thermal Conductivity Analyser
JCT FTC300 Thermal
FTC300 Conductivity Analyser
FTC300 Analyser
Conductivity Analyser
Thermal Conductivity Analyser
Êtes-vous intéressé par le produit JCT FTC300 Thermal Conductivity Analyser du fabricant JCT avec le code FTC300? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour JCT FTC300 Thermal Conductivity Analyser de notre équipe de support en direct maintenant!
ApplicationsFor extractive gas analysisFor quality and process monitoringFor continuous determination of the concentration of single gas components like e.g. H2, CO2, O2, He, Ar, CH4, N2, NH3,CO, SF6 in binary gas mixtures in the gas-, food-, insulating glass- and thermal treatment-industryBenefitsHigh sensitivity e.g. 0....0,5 Vol.% H2 in N2; noise < 10 ppm H2 in N2Durable measuring cellSequential measurement of 15 binary gas mixtures due to multi gas modeOffsetting the cross sensitivity of an interfearing component possibleQuick response time (T90 < 1 s)Comfortable menu and operater navigation at calibration and parameterisationClassic two-point calibration or one-point calibrationRS232-access to all (measuring) data and parametersFeaturesPrecise and long term stable gas analysis according to the thermal conductivity measuring principleMicroprocessor based128 x 64 point graphic displayOperation via 3 keys or PC-based service programSmall robust design in aluminium housing for field operation (protection class IP65)Linear electrically isolated current output 4....20 mA, start- and end point concentration freely selectable3 configurable relays for alarm message and device statusPrecise linearisation for binary gas mixtures like e.g. H2, He, CO2, CH4 in N2 or Ar in the permanent storage; additional customer specific linearisation with polynomial of 6th order Indication in ppm or Vol.%, resolution adjustable up to 1 ppmPressure resistant (20 bar) and vacuum leak-tight gas path out of stainless steel (SS316Ti)