Nom du Produit: Landefeld 2/2-way solenoid valves made of brass, Eco-Line
Marque: Landefeld
Code Produit: 2/2-way solenoid valves made of brass, Eco-Line
Mots-clés: Landefeld
Landefeld valves made
Landefeld of Eco-Line
2/2-way solenoid valves made
2/2-way valves made brass,
Landefeld made brass, Eco-Line
solenoid valves made of brass, Eco-Line
solenoid valves of brass, Eco-Line
Landefeld valves made of brass,
Landefeld 2/2-way solenoid of brass,
Landefeld 2/2-way solenoid valves made brass,
solenoid valves made brass, Eco-Line
2/2-way made brass,
2/2-way of brass,
Landefeld 2/2-way solenoid of brass, Eco-Line
2/2-way valves made of brass, Eco-Line
2/2-way solenoid valves Eco-Line
2/2-way solenoid valves made of
Landefeld solenoid valves of
Landefeld 2/2-way solenoid valves made of Eco-Line
solenoid made Eco-Line
Êtes-vous intéressé par le produit Landefeld 2/2-way solenoid valves made of brass, Eco-Line du fabricant Landefeld avec le code 2/2-way solenoid valves made of brass, Eco-Line? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Landefeld 2/2-way solenoid valves made of brass, Eco-Line de notre équipe de support en direct maintenant!
Description Materials: Bodies: brass, internal parts: brass / stainless steel, seal: NBR Temperature range: -10°C to +80°C, environment: max. +65°C Power consumption: Direct current: 13 W, alternating current: 22 VA (draw: 40 VA) Media: Compressed air, neutral gases, water, neutral low-viscosity media, other media on request Installation position: With upright magnets Voltages: Standard: 24 V=, 230 V AC, upon request: other voltages Protection class: IP 65 Solenoid: P (plug size 3) Optional: FKM seal (-10°C to max. +130°C) -V, EPDM seal for air and warm water (-10°C to max. +120°C) -EP Information: These valves are generally delivered with coils and plugs! Warning: For opening or closing, servo-controlled valves require a pressure difference between the valve inlet and valve outlet. The pressure difference is given as minimum pressure. There is a pressure compensation in the valve, resulting that no or little medium is used at the valve outlet, the valve will no longer function (it opens or closes unreliably). SLP 18 230V SLP 18 24VAC SLP 14 24V= SLP 14 230V SLP 14 12V= SLP 38 24V= SLP 38 230V SLP 38 12V= SLP 38 24VAC SLP 12 24V= SLP 12 230V SLP 12 EP 230V SLP 12 12V= SLP 12 24VAC SLP 34 24V= SLP 34 230V SLP 34 24VAC SLP 34 24VAC SLP 10 24V= SLP 10 230V