Nom du Produit: Meggitt Vibro-Meter GSI127 Galvanic Separation Unit
Marque: Meggitt
Code Produit: Vibro-Meter GSI127
Mots-clés: Meggitt
Meggitt GSI127 Galvanic
GSI127 Unit
Meggitt Vibro-Meter GSI127 Galvanic Separation
Meggitt Vibro-Meter GSI127 Separation
Meggitt GSI127 Unit
Vibro-Meter Galvanic
Vibro-Meter GSI127 Separation Unit
GSI127 Galvanic
Meggitt GSI127 Galvanic Separation Unit
Vibro-Meter Unit
Meggitt GSI127 Galvanic Unit
Galvanic Unit
Galvanic Unit
Vibro-Meter Galvanic Separation
Separation Unit
Meggitt Galvanic Unit
Meggitt Vibro-Meter GSI127 Galvanic
Galvanic Separation Unit
Vibro-Meter Separation
GSI127 Unit
Galvanic Separation Unit
Êtes-vous intéressé par le produit Meggitt Vibro-Meter GSI127 Galvanic Separation Unit du fabricant Meggitt avec le code Vibro-Meter GSI127? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Meggitt Vibro-Meter GSI127 Galvanic Separation Unit de notre équipe de support en direct maintenant!
Galvanic separation unit for use with vibration sensor (CA, CE, PV and VE), dynamic pressure sensor (CP) or proximity sensor (TQ) measurement chains.The GSI127 galvanic separation unit is a high-quality, high-reliability unit for use with the IPC704 signal conditioner (used by CA accelerometers and CP dynamic pressure sensors), current-output accelerometers such as the CE134, CE281 and CE311, constant-current voltage-output sensors such as the CE110I, PV102 and CE680Mx11, the IQS450 signal conditioner (used by TQ proximity sensors) or the VE210 velocity sensor.The GSI127 has a configurable transfer function and provides a voltage output. It is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres).FeaturesPower supply and galvanic separation unit for sensors and signal conditioners with a current output or a voltage output4 kVRMS galvanic separation between the sensor side and the monitor side50 VRMS galvanic separation between the power supply and the output signal (floating output)?A to mV transfer function for long distance current-signal transmission, V to V transfer function for short-distance voltage-signal transmissionCertified for use in potentially explosive atmospheres PARAMETER VALUE (IMPERIAL | METRIC) Output type Voltage (2-wire) Measurement system CA vibration, CP dynamic pressure, TQ proximity or VE velocity Sensor or signal conditioner IPC704 signal conditioner (CA and CP sensors), CE sensors with a current output, IQS450 signal conditioner (TQ sensors) and VE210 sensor Input signal range (sensor side) 0 to 20 mA or 0 to 20 VDC Output signal range (monitor side) 2 to 20 VDC Transfer function (sensitivity) 1 V/mA ±1%, 3.2 V/mA ±1%, 1 V/V ± % or ?1 V/V ±1% Transfer function (output offset voltage) 7 VDC ±0.2 VDC, 8 VDC ±0.2 VDC or 10 VDC ±0.2 VDC Frequency range DC to 20000 Hz Linearity <0.2% Galvanic separation 4 kVRMS Operating temperature range 32 to 158 °F | 0 to 70 °C Hazardous area certifications Ex nA [ia Ga], AEx nA [ia Ga]