Nom du Produit: Varec 8200 Current Output Transmitter
Marque: Varec
Code Produit: 8200
Mots-clés: Varec
Varec Current Output Transmitter
Current Output
Varec Current
Varec Output
Varec 8200 Current Transmitter
Current
8200 Current Output Transmitter
Varec Current
Varec 8200
8200 Transmitter
Output
Current Transmitter
Varec Current Transmitter
8200 Output Transmitter
Current
8200 Current Output Transmitter
Varec 8200
8200 Output Transmitter
Current Output
Current Output Transmitter
Êtes-vous intéressé par le produit Varec 8200 Current Output Transmitter du fabricant Varec avec le code 8200? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Varec 8200 Current Output Transmitter de notre équipe de support en direct maintenant!
The 8200 Current Output Transmitter (COT) is a precision analog transmitter designed to relay level information using a 4-20 mA or 10-50 mA signal to the control room.SpecificationsAccuracy 0.25% at 100% span, 0.35% at 45% span Output 4?20 mA or 10?50 mA, jumper selectable 2-wire Adjustment Range: 50?100% Span: 45?105% Power 15 to 48 VDC (user supplied) 115 VAC ± 10% 50/60 Hz (on board 30 VDC power supply) 230 VAC ± 10% 50/60 Hz (on board 30 VDC power supply) Operating Voltage 15 VDC – minimum 48 VDC – maximum Limit Switches Ratings: 20 A @ 125, 250, 460 VAC 10 A @ 125 VAC Tungsten filament Lamp Load: 1 HP @ 115 VAC, 2 HP @ 250 VDC 1/2 A @ 125 VDC, 0.25 A @ 250 VDC normally open or normally closed Approvals FMus? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85 °C: Flameproof Class I, Zone 1, AEx d IIB T5 Ta=+85°C, cFM? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85°C: Flameproof Class I, Zone 1, Ex d IIB T5 Ta=+85°C, ATEX ? Flameproof ? Ex II 2 G, Ex d IIB T5 Ta = +85°C IECEx ? Flameproof ? Ex d IIB T5 Ta = +85°C IP66 (NEMA 4)OptionsPower Rating 15 ? 48 VDC 115 VAC 220 ? 240 VAC 02 Level Range 0 to 12.5 ft 0 to 25 ft 0 to 50 ft 0 to 100 ft 0 to 3.75 m 0 to 7.5 m 0 to 15 m 0 to 24 m 03 Approvals FMus? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85 °C: Flameproof Class I, Zone 1, AEx d IIB T5 Ta=+85°C cFM? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85°C: Flameproof Class I, Zone 1, Ex d IIB T5 Ta=+85°C ATEX ? Flameproof ? Ex II 2 G, Ex d IIB T5 Ta = +85°C IECEx ? Flameproof ? Ex d IIB T5 Ta = +85°C 04 Calibration & Limit Switches 2 SPDT Switches (Normally Open) 4 SPDT Switches (Normally Open) Reverse Reading Reverse Reading with 2 SPDT Switches (Normally Open) Reverse Reading with 4 SPDT Switches (Normally Open) 05 Junction Box None With a Junction Box