| Encoder characteristics | IncrementalMRP 2080 | AbsoluteMRP 2010 |
| Measuring standard | DIADUR circular scale | |
| Signal periods | 2048 | |
| System accuracy* | ±7” | |
| Position error per signal period | ±1.5” | |
| Repeatability | From both directions: 3” | |
| RMS position noise | Typically 0.07” | Typically 0.01” |
| Interface | ? 1 VPP | EnDat 2.2 |
| Ordering designation | – | EnDat22 |
| Position values per revolution | – | 25 bits |
| Clock frequencyCalculation time tcal | – | ? 16 MHz? 7 µs |
| Reference marks | 1 | – |
| Cutoff frequency –3 dB | ? 210 kHz | – |
| Electrical connection | 14-pin header; adapter cable with quick connector as accessory | 12-pin |
| Cable length | ? 30 m (with HEIDENHAIN cable) | |
| Supply voltage | DC 5 V ±0.25 V | DC 3.6 V to 14 V |
| Power consumption (max.) | 5.25 V: ? 700 mW | 3.6 V: ? 0.6 W 14 V: ? 0.7 W |
| Current consumption (typical) | Without load: IP = 60 mA; max. 120 mA With load: max. 130 mA | 5 V: 85 mA (without load) |
| * Please select when ordering | ||
| Bearing properties | IncrementalMRP 2080 | AbsoluteMRP 2010 |
| Shaft | Hollow through shaft D = 10 mm | |
| Max. permissible axial load3) | 50 N (centered load) | |
| Max. permissible radial load3) | 45 N | |
| Max. permissible tilting torque3) | 0.8 Nm | |
| Contact stiffness | Axial: 54 N/µmRadial: 153 N/µm(calculated values) | |
| Resistance to tilt | 2.16 Nm/mrad (calculated value) | |
| Mechanically perm. speed | 2000 rpm | |
| Moment of friction | ? 0.020 Nm | |
| Starting torque | ? 0.010 Nm | |
| Max. transferable shaft torque3) | 0.3 Nm | |
| Moment of inertia of rotor | 3.5 · 10–6 kgm2 | |
| Radial guideway accuracy | Measured at distance h = 52 mm from the ball race: ? 0.60 µm | |
| Non-reproducible radial guideway accuracy | Measured at distance h = 52 mm from the ball race: ? 0.70 µm | |
| Axial guideway accuracy | ? ±0.3 µm | |
| Axial runout of the surface | ? 8 µm | |
| Wobble of the axis | 2.5” | |
| Vibration 55 Hz to 2000 HzShock 6 ms | ? 200 m/s2 (EN 60068-2-6)? 100 m/s2 (EN 60068-2-27)(without load) | |
| Protection EN 605292) | IP001) | |
| Operating temperatureStorage temperature | 0 °C to 50 °C0 °C to 50 °C | |
| Relative air humidity | ? 75 % without condensation | |
| Mass | 0.12 kg (without cable or connector) | |
| 1) Electromagnetic compatibility must be ensured in the complete system through appropriate installation measures2) When mounted3) Purely static load, without additional vibrations or shock load | ||