97% customer satisfaction based on last 45 days of sales
Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Get the best price and fastest delivery for Kirchgaesser FTR20 Flow Indicator for Bulk Solids from Kirchgaesser. Imtek Engineering offers worldwide industrial equipment supply with expert support.
| Detection range: | Max. 20 m |
| Operating frequency: | 24.15 GHz ± 80 MHz |
| Electrical connection: | Cable gland M20Thread ANSI ½ NPTBinder connector type M12 series 713/763Harting connector type HAN8D |
| Output signal: | Relay SPDTCurrent 4...20 mASolid-state relay |
| Power supply: | 85...253 VAC, 50/60 Hz20...60 VDC or 20...30 VAC, 50/60 Hz |
| Housing: | PolyesterStainless steel 316L |
| Process connection: | Thread R 1½ in accordance with EN 10226Thread G 1½ in accordance with ISO 228-1Thread 1½ NPT in accordance with ANSI/ASME |
| Optional process connection: | FlangeSight glassHigh-temperature adapterHigh-pressure adapterMounting bracketStructured accessories FAR50, FAR51, FAR52, FAR53, FAR54 and FAR55Individual customer solutions |
| Main wetted parts: | Contactless installation: noMounting: 316Ti or Aluminum, PTFE or ceramic |
| Ambient temperature: | -40...70 °C |
| Process temperature: | Contactless installation: anyMounting: -40...+70 °C, with high-temperature adapter -40... +450 °C |
| Process pressure: | Contactless installation: anyMounting: 0.5...6.8 bar (50...680 kPa) abs., with high-pressure adapter 0.5...21 bar (50...2100 kPa) abs. |
| Protection acc. to EN 60529: | IP 66 |
| Vibration resistance - Endurance stress with sliding frequency acc. to EN 60068-2-6: | Excitation mode: sineFrequency range: 10...55 HzAmplitude: 0.75 mm peak constantSpeed of sweep: 1 oct / minExcitation direction: 3 directions (X, Y, Z)Number of cycles: 20 / directionTest duration: approx. 1 h 38 min / directionTest temperature: room temperature |
| Marking acc. to 2014/34/EU (ATEX): | ATEX II 1/2D Ex ta/tb IIIC T102°C Da/Db IP66, ATEX II 2D Ex tb IIIC T102°C Db IP66 (BVS 11 ATEX E 032) |
| Marking acc. to IECEx: | Ex ta/tb IIIC T102°C Da/Db IP66, Ex tb IIIC T102°C Db IP66 (IECEx BVS 11.0016) |
| Marking acc. to CSA: | CSA C/US General PurposeCSA C/US Class II, Div. 1, Group E-G |
| Marking acc. to EAC Ex: | EAC Ex ta/tb IIIC T102°C Da/DbEAC Ex tb IIIC T102°C Db |
| Radio approval: | R&TTE according to EN 300440-2FCC Rule Parts 15CIC according to RSS-210 Issue 8, RSS-GEN Issue 3 and RSS-102 Issue 4 |
Flow Indicator for Bulk Solids