| Measuring range: | Max. 600 bar (thinfilm)Max. 60 bar (ceramic diaphragm)Other measuring ranges are available on request |
| Electrical connection: | Hirschmann connector type G4 |
| Output signal: | Provided by the Kirchgaesser evaluation and/or display unit COMBA-EX |
| Process connection, sensor: | Pipe thread G1¼, flush-mounted ceramic sensorPipe thread G½, internal ceramic sensorPipe thread G½, flush-mounted thinfilm sensorPipe thread G½, internal thinfilm sensorPipe thread G¼, internal thinfilm sensorSocket nipple DN10 (acc. to DIN 20043), thinfilm sensorFlange DN40 PN6 with extensionHydrostatic transducer (submersible sensor) |
| Housing: | Stainless steelConnector: Plastic |
| Time constant of damping: | Approx. 20 ms |
| Power supply: | Provided by the Kirchgaesser evaluation and/or display unit COMBA-EX |
| Current consumption: | 3 mA |
| Protection acc. to EN 60529: | IP 65 (hydrostatic transducer IP68) |
| Marking acc. to 2014/34/EU (ATEX): | I M1 Ex ia I (KDB 08ATEX027) |
| Ambient temperature: | -20...+60 °C |
| Process temperature: | -20...+60 °C |
| Measuring uncertainty: | Max. ± 1 % of end value, typ. ± 0.5 % of end valu |