Product Name: Varec 8200 Current Output Transmitter
Brand: Varec
Product Code: 8200
Tags: Varec
8200 Output Transmitter
8200 Transmitter
Varec 8200 Output
8200 Current Transmitter
Output Transmitter
8200 Output
Current Output Transmitter
8200 Current
Varec 8200 Current Transmitter
Current Output
Varec Current
Current
Current Output Transmitter
Transmitter
Output
Varec 8200 Current
Varec Current Transmitter
Current Transmitter
Varec 8200 Current Output Transmitter
Current Output Transmitter
您对制造商Varec的产品Varec 8200 Current Output Transmitter,代码为8200感兴趣吗?立即联系我们获取报价。Imtek Engineering,世界上最快最可靠的工业设备供应商,将为您提供最佳报价!
Get Offer With E-Mail: info@im-tek.com
Get a offer for Varec 8200 Current Output Transmitter from our live support team now!
The 8200 Current Output Transmitter (COT) is a precision analog transmitter designed to relay level information using a 4-20 mA or 10-50 mA signal to the control room.SpecificationsAccuracy 0.25% at 100% span, 0.35% at 45% span Output 4?20 mA or 10?50 mA, jumper selectable 2-wire Adjustment Range: 50?100% Span: 45?105% Power 15 to 48 VDC (user supplied) 115 VAC ± 10% 50/60 Hz (on board 30 VDC power supply) 230 VAC ± 10% 50/60 Hz (on board 30 VDC power supply) Operating Voltage 15 VDC – minimum 48 VDC – maximum Limit Switches Ratings: 20 A @ 125, 250, 460 VAC 10 A @ 125 VAC Tungsten filament Lamp Load: 1 HP @ 115 VAC, 2 HP @ 250 VDC 1/2 A @ 125 VDC, 0.25 A @ 250 VDC normally open or normally closed Approvals FMus? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85 °C: Flameproof Class I, Zone 1, AEx d IIB T5 Ta=+85°C, cFM? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85°C: Flameproof Class I, Zone 1, Ex d IIB T5 Ta=+85°C, ATEX ? Flameproof ? Ex II 2 G, Ex d IIB T5 Ta = +85°C IECEx ? Flameproof ? Ex d IIB T5 Ta = +85°C IP66 (NEMA 4)OptionsPower Rating 15 ? 48 VDC 115 VAC 220 ? 240 VAC 02 Level Range 0 to 12.5 ft 0 to 25 ft 0 to 50 ft 0 to 100 ft 0 to 3.75 m 0 to 7.5 m 0 to 15 m 0 to 24 m 03 Approvals FMus? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85 °C: Flameproof Class I, Zone 1, AEx d IIB T5 Ta=+85°C cFM? Explosion Proof ? CIass I, Division 1, Groups C & D T5 Ta = +85°C: Flameproof Class I, Zone 1, Ex d IIB T5 Ta=+85°C ATEX ? Flameproof ? Ex II 2 G, Ex d IIB T5 Ta = +85°C IECEx ? Flameproof ? Ex d IIB T5 Ta = +85°C 04 Calibration & Limit Switches 2 SPDT Switches (Normally Open) 4 SPDT Switches (Normally Open) Reverse Reading Reverse Reading with 2 SPDT Switches (Normally Open) Reverse Reading with 4 SPDT Switches (Normally Open) 05 Junction Box None With a Junction Box