im-tek.com

Greyline ISM 5.0 Insertion Magmeter

Greyline

Product Code: ISM 5.0
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline ISM 5.0 Insertion Magmeter

electromagnetic with no moving partssimplified hot tap insertion designinstalls in 3-72" (80-1800 mm) diameter pipesselectable 4-20mA, 0-5V or 0-10V output0-500Hz frequency outputscalable pulse outputAccurate, Low Cost Alternative to Full-bore Magnetic Flow MetersMeasure flow of water and conductive liquids in full pipes from 3 to 72" (80 to 1800 mm) diameter.The ISM 5.0 dual pair electrode sensor inserts through a tap in the pipe wall. It can be easily installed in new pipe systems or by hot tap in pressurized pipes with flowing liquids. There are no moving parts so obstruction to flow and pressure drop is minimal. Installation through a full port ball valve allows easy retraction and reinsertion without shutting down flow. The insertion depth is adjustable according to the pipe diameter and an insertion depth gauge is supplied with each flowmeter. The optional Installation Hardware Kit includes a branch outlet, close nipple and full port 1” isolation valve. The ISM 5.0 Insertion Magmeter senses flow using a low maintenance electromagnetic design with no moving parts. The dual-electrode sensor and continuous auto-zero function provides high accuracy – even at low flow rates. State-of-the-art electronics and patented design features help maintain its NIST traceable accuracy over time.No Onsite Calibration RequiredBased on your pipe type and size, liquid and flow rate each ISM 5.0 Insertion Magmeter is shipped from our factory configured for your application and ready to install. Connect the isolated 4-20mA output to control system or remote display, or use the relay pulse output.Installs through a Ball Valve into the pipeHow It WorksThe ISM 5.0 Insertion Magmeter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the ISM flow meter, electrodes measure the voltage increase to accurately calculate flow. Four electrodes measure the induced voltage on opposite sides of the sensor. The voltage readings are sampled and averaged.The ISM 5.0 Insertion Magmeter measures flow of electrically conductive liquids (20 µS/cm or greater) in full pipes. For proper measurement on plastic pipes the electromagnetic flow meter requires electrical grounding by connection to grounding rings or ground probes inserted into the pipe. Readings are not affected by the fluid temperature, pressure or viscosity.INSERTION MAGMETER SPECIFICATIONSProvide a Greyline ISM 5.0 Insertion Magmeter complete with all installation hardware necessary to enable insertion and removal of the meter without system shutdown. The flow meter shall be hand-insertable up to 400 psi. For installations in non-metallic pipe, install grounding rings or probes. Materials of construction for wetted metal components shall be 316 SS.  The flow meter shall average velocity readings from two sets of diametrically opposed electrodes.  Each flow meter shall be individually wet-calibrated against a primary volumetric standard that is accurate to within 0.1% and traceable to NIST*.  A certificate of calibration shall be provided with each flow meter. Accuracy shall be within ± 1% of rate from 2-20 ft/s. Overall turndown shall exceed 100:1.Output signals shall be completely isolated and shall consist of the following: (1) analog output; 4-20mA, 0-10V, or 0-5V jumper selectable, (1) scalable dry contact output for totalization, and (1) high resolution frequency output for use with peripheral devices.  ISM 5.0-B for Bi-directional applications shall provide additional contact outputs for direction and flow totalization in each direction. Each flow meter shall be certified to NSF Standards and covered by the manufacturer’s two-year warranty.* National Institute of Standards and TechnologyOptional Flow DisplayD-100 Series Display Module for network interface and local / remote indication of flow rate and total.

Recommended Products For Greyline


Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline DFM 6.1 Doppler Flow Meter
Greyline DLT 2.0 Differential Level Transmitter
Greyline DFS 5.1 Doppler Flow Switch
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline ISM 5.0 Insertion Magmeter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline LIT25 Level Indicating Transmitter
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline PDFM 5.1 Portable Doppler Flow Meter
Amg Pesch DAD-15 Double-Piston Quarter Turn Actuator
Mahle Pi 281180/21-058 Duplex Filter
Dropsa 1113220 - 300 MICRON Filter
Scheuch zsm 1252 Rotary Valve
MBS MLM 114 n 32 12 1 3000 Multiflo Heat Exchanger
Coax VSV-F 80 2/2 Way Externally Controlled Coaxial Valve
Mollet DF28A1C5G0ET1LE 0500KD Rotating Vane Level Indicator
Negele TFP Series Temperature Sensor With Built-in System ESP
WARNER ELECTRIC ERS Fenix 10 Elevator Brakes
Samson ANSI CLASS 300 Plug
Italvibras MVSS 15/400-S02 601345 Electric Vibrator in Stainless Steel
MBS MLW 60 7 12 1 3000 Sanitary Mixflo Multitube
Vogel MKU2-13DC00000 428 Single Line Pump
Elwa KVD8-210 50Hz Preheater
Mp Filter FMP1352BAG2A10N Filter
American Industrial AB-703-TP Heat Exchanger
Atos Sp-Cau-220Dc Coil
Nachi SS-G03 Series Wet Type Solenoid Operated Directional Control Valve
Vega VEGAPULS Air 42 Autarkic, Continuous Level Measurement for Liquids and Bulk Solids
Amot 4BODF11001-00-DEL Model B Thermostatic Valve
Wilkerson M16-C4-000
Bardiani TPHGM08003A Seal Ring
Giacomello Rl/G1-1”-S2 L Level Switch
Bürkert Type 8690 Id.Nr.: 00227220 Pneumatic Control Unit