Greyline SLT 5.0 Ultrasonic Level & Flow Monitor

Greyline

Product Code: SLT 5.0
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline SLT 5.0 Ultrasonic Level & Flow Monitor

Measure Level or Open Channel FlowUser-Friendly Calibration SystemIsolated 4-20mA (1000 ohm)False Echo Rejection2 Programmable Control RelaysElectrical Surge ProtectionIntrinsically Safe Sensor OptionPlug and Play Relay and Data Logger OptionsSLT 5.0 Level & Flow MonitorUse this versatile instrument to continuously measure, display, transmit and control liquid level in storage tanks and pumping stations, or to monitor and totalize Open Channel Flow through any flume or weir. Mount the non-contacting ultrasonic sensor above the liquid being measured and install the watertight electronics enclosure nearby. Features a user-friendly keypad calibration system, backlit LCD display, an isolated 4-20mA output and 2 programmable control relays.Calibration is easy with the built-in 5 button keypad. The SLT 5.0 offers simple menu selection of measurement units (gallons, liters etc.), calculates volume in horizontal round tanks, or flow rate (and total) through any flume or weir.For hazardous locations, the ultrasonic sensor is rated Intrinsically Safe with an optional safety barrier. The standard PVC and Teflon Sensor is rated for measurement ranges up to 32 ft/10 m, or select optional sensors for flange-mount or applications requiring longer measurement range. Options include 4 additional control relays (6 total) and a built-in 2-million point Data Logger with USB output to Flash memory sticks.Contact Greyline Instruments for specific recommendations in your application.LEVEL & FLOW MONITOR SPECIFICATIONSSCOPE: This specification covers a non-contacting ultrasonic Level/Flow Monitor as manufactured by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This instrument shall provide for indicating, transmitting and control of the material level in a vessel or proximity of a target to the instrument sensor, and indicating, transmitting, and totalizing of the flow rate through a flume, weir, or other primary measuring device.A. GENERALLevel/Flow Monitor to consist of a non-contacting ultrasonic sensor, connecting cable, and a remote enclosure with indicating, transmitting and controlling electronics.Measurement accuracy shall be ±0.25% of Range or 2 mm (0.08"), whichever is greater, and shall be automatically temperature compensated.Sensor cable length shall be as required by installation, not to exceed 500' (152 m).System shall have no moving parts and shall not contact the material being measured.Shall include PC software program disk to determine open channel flow calibration values for non-standard flumes and weirs.B. SENSING ELEMENTSensor shall be constructed of PVC and Teflon.The sensor shall have a minimum deadband or blanking of 12" (305 mm) and a maximum range of 32 ft. (10 m), and have an operating frequency of 42 kHz with an ultrasonic beam angle of 8 Degrees.Sensor shall withstand accidental submersion to 20 psi.Sensor operating temperature shall be from -40°F to 150°F (-40°C to 65°C).Sensor shall include integral temperature sensor. Temperature sensors requiring separate mounting and wire runs shall not be accepted.C. SENSOR CONNECTING CABLEProvide RG62AU coaxial cable 25' (7.6m) continuous length, with waterproof, potted bond to the Sensor head.Extended sensor cable shall be RG62AU coaxial to a maximum of 500' (152m). Cable shall be spliced with screw terminal connections in manufacturer's recommended steel NEMA4 Junction Box.Level and temperature signals shall be conducted on one single coaxial cable. Separate or multiple-conductor cables shall not be accepted.Sensor cable shall be installed in grounded metal conduit.D. TRANSMITTERThe transmitter shall provide for field-calibration via built-in 5-key calibration system with menu selection of parameters. Systems requiring calibration by Parameter codes, BCD switches or external calibrators shall not be accepted.Calibration data shall be password protected and permanently stored through power interruptions for a minimum of 12 months.Field calibration shall allow selection and automatic conversion of measurement units, measurement span and control relays.The transmitter shall provide for field calibration in user-selected Range, Level or Open Channel Flow modes. Flow mode shall allow calibration to common primary metering devices, plus allow entry of calibration formula for non-standard flumes, weirs or open channels.Transmitter shall permit field programmable damping to smooth output with turbulent level.Transmitter operating temperature shall be from -5° to 140°F (-20° to 60°C). Transmitter shall contain a thermostat-controlled enclosure heater for condensation protection below 30°F (-1°C).Transmitter shall have an isolated 4-20mA output rated for 1000 ohm maximum load with menu-selectable 0-5VDC alternative.Provide two relay contacts rated 5 amp SPDT programmable for single set point alarms, dual set point pump control, pump alternation, temperature alarm, flow totalizer pulse and/or echo loss alarm.Provide a white, backlit matrix LCD display indicating flow rate, level, velocity, totalizer and relay states in user-selected engineering units.Transmitter display indicating level or flow rate, units of calibration, totalizer and relay states shall be visible without opening cover.Transmitter shall be housed in a wall-mount, watertight NEMA4X (IP66) enclosure with hinged, clear cover. Mounting hardware shall be included.Transmitter electronics shall be surge protected on AC power input, sensor and 4-20mA outputs.Transmitter power input shall be 100-240VAC 50-60Hz with power consumption of 3.5 Watts or less.The transmitter shall permit plug-in field installation and auto-detection of optional accessories including data logger and additional control relays.E. OPTIONAL FEATURES FOR INSERTION AS REQUIREDHave 4 additional (6 total) control relays, rated 5 amp SPDT and programmable for single set point alarms, dual set point pump control, pump alternation, temperature alarm, flow totalizer pulse and/or echo loss alarm.Sensor, connecting cable and junction boxes shall be rated intrinsically safe to Class I,II,III, Div. I,II, Groups C,D,E,F,G.Have a thermostat controlled enclosure heater for Transmitter operation at temperatures below freezing.Have an all-Teflon sensor Model PZ32TE rated intrinsically safe when connected through an approved safety barrier, and rated for operation from -40°F to 170°F (-40°C to 76°C).Have a PVC and Teflon sensor Model PZ56 rated for measurement range on liquids up to 50 ft. (15.6 m).Have a Teflon-faced flange mount sensor model PZ34TxF rated for 32 ft (10 m) measurement range. Specify flange size of 4” or 6”.Have manufacturer's recommended enclosure sunscreen to permit Transmitter mounting in direct sunlight.Have manufacturer's recommended Sensor sunscreen to permit temperature-compensated Sensor mounting in direct sunlight.Have manufacturer's recommended Panel Mount Flange assembly for enclosure installation.Have a built-in 2 million point Data Logger with USB output to flash drive or mass storage device. Include Windows software.Have power input of 9-32VDC and power consumption of less than 3.5 Watts.F. MANUFACTURERLevel/Flow Monitor shall be Model SLT 5.0 as manufactured by Greyline Instruments Inc. and shall be warranted against defects in materials and workmanship for one year.

Recommended Products For Greyline


Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline ISM 5.0 Insertion Magmeter
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline LIT25 Level Indicating Transmitter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline DFM 6.1 Doppler Flow Meter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline DLT 2.0 Differential Level Transmitter
Greyline DFS 5.1 Doppler Flow Switch
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Coax RMQ15PC Valve
Omal EA 0035 A5 C0 00 Actuator
Control Techniques UNI 1403 Ac Drive
Dropsa 0888058C Small Pump
Alfa Valvole A20T C135187 Single Acting Pneumatic Actuator Valve
Alfa Laval 9612075334 VALVE LKB-2 DN80 DIN M/NL FPM 304L
Gefran PKIT591 Kit
Edur BC25-121/0157-2900 Single Stage Close-Coupled Pump
Grundfos CR 1-4 A-FGJ-A-E-HQQE Multi Stage Pump
Alfa Laval 9613360433 UNIQUE SSV 38/1½ INCH 022 RA W-W 0.8/BLASTED EPDM SHUT OFF NC
Gemü 687 25D 8C3131F/N 1500 Diaphragm Valve
Atos DHI-0 613 X 24DC Valve
Fybroc 3x4x10 Series 5530 Dry Pit Vertical Sump Pump
Flovex BEM 1504 Fixed Straight Tubesheet Heat Exchangers
Alfa Laval LKLA Ø133 101.6/DN100 NO 9612271307 Actuator
Atlas Copco 2901194502 Filter Kit
Intra ITABAR FTM Flow Sensor
Sitema KFH 125 KFH 125 70 Locking Unit
Ziehl MS220KA Relay
Stahl 8570/12-507-S-XX-X-XX-XXX Plug
Hengstler AC58/1217AK.42SGD Absolute Encoder
Omal RV2IXA20M12MD Sensor
Mp Filter FHB 065-3-B-A-F1-A10-N-P01 Filter
Asco Joucomatic 55102005 Valve