im-tek.com

Greyline PTFM 1.0 Portable Transit Time Flow Meter

Greyline

Product Code: PTFM 1.0
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline PTFM 1.0 Portable Transit Time Flow Meter

Recommended for fluids like water, glycol, oils and chemicals. Use it for calibrations, troubleshooting, flow surveys and as a temporary transmitter to replace inline flowmeters.The PTFM 1.0 ultrasonic transducers clamp-on the outside of pipes from 2" to 48" (50 to 1200 mm) diameter. The ultrasonic signal works through common pipe materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. Transducers can be mounted without shutting down flow and there is no obstruction or pressure drop. It measures and totalizes forward and reverse flow.The PTFM 1.0 Portable Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.User-Friendly Operating SystemCalibration is easy with the onscreen menu system. Just enter the pipe diameter, wall thickness and pipe material. The PTFM 1.0 is powered by an internal, rechargeable NiMH battery or can be operated continuously with AC power adapter. Each PTFM 1.0 includes a watertight carry case, transducer set, cables and mounting clamps.Built-in Data Logger with Windows Software IncludedSet up the 300,000 point data logger to store time and date-stamped flow readings from 10 second to 5 minute intervals. View the convenient on-screen 'Flow Report' where total, minimum, maximum and average flow rates are stored in a 24 hour daily summary.Transfer flow logs to your PC or laptop through the PTFM 1.0's USB output. Greyline Logger software (included) displays data in both graph and table formats with one-click export to Microsoft Excel®, images or CSV files for use in other programs.PORTABLE ULTRASONIC FLOW METER SPECIFICATIONSSCOPE: This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.GENERAL:Each portable Transit Time flow meter shall have the following design features and engineering specifications:A. PERFORMANCE SPECIFICATIONSThe ultrasonic flow meter shall have an accuracy of ±1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.Shall operate on clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 39 ft/sec (±0.02 to 12 m/sec).Operate on the following pipe materials: carbon steel, stainless steel, PVC, PVDF, fiberglass, galvanized steel, mild steel, ductile iron, glass, copper, brass and pipes with bonded liners including cement, epoxy, rubber and Teflon.Operate on AC power or from internal, rechargeable batteries.B. TRANSDUCERSThe flow meter shall have a dual transmitting/receiving, clamp-on transducers operating at 1.28MHz.The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).The standard transducer pair shall be designed to install on pipes with nominal diameter ranging from 2" to 48" (50 mm to 1200 mm).Have 12 ft (3.4 m) length coaxial cables from the electronics with BNC connectors to transducers.Shall include manufacturer's recommended transducer coupling compound. Shall include stainless steel mounting hardware, pipe clamps and aluminum alignment bar.Shall include BNC seal jackets for transducer operation in wet or submerged conditions.C. ELECTRONICSHave a portable ABS electronics enclosure with a padded, watertight IP67 carrying case. Total weight shall be less than 15 lbs (7 kg).Electronics shall be designed for continuous operation at temperatures from -5° to 140°F (-20° to 60°C).Have a built-in 5-key calibration keypad with operator selection of parameters through visual prompts from a menu calibration system. Systems requiring calibration by Parameter codes or external calibrators shall not be accepted.Have user-selectable menu languages including English, French and Spanish.Have a white, backlit matrix display indicating flow in user-selected engineering units, totalized flow, units of calibration, and signal strength.Have display backlight brightness adjustment for reduced power consumption.Have flow proportional 4-20mA output rated to maximum resistive load of 500 ohms.Have a built-in 300,000 point data logger, USB output and connecting cables. Data logger shall support time and date-stamped logging and generate formatted flow reports including total, average, minimum, maximum and times of occurrence.Include Windows software for data log retrieval, graphing and export.Have automatic signal strength and signal confidence monitoring.Have keypad adjustable minimum flow rate cutoff.Shall include an external with CE/UL approved charger with 100-240VAC 50/60Hz input.Shall include an internal NiMH rechargeable battery with minimum capacity for 18 hours continuous battery operation.Have a battery status indicator with automatic low battery shut off and battery overcharge protection.Have user-selectable "sleep mode" synchronized to data logger sample rate for reduced battery power consumption.D. OPTIONAL FEATURES FOR INSERTION IN SPECIFICATION AS REQUIRED:Include additional 150 g. manufacturer's recommended ultrasonic sensor coupling compound.Include 50 ft (15 m) length Sensor Cable extension complete with connecting plugs.E. MANUFACTURERThe instrument shall be a Model PTFM 1.0 Portable Transit Time Flow Meter as manufactured by Greyline Instruments Inc., and warranted against defects in materials and workmanship for one year.Non-Contacting Clamp-on Ultrasonic Transducers Works on Metal and Plastic PipesLarge Backlit Flow Rate Display and TotalizerIsolated 4-20mA OutputBuilt-in 5-Key Calibrator300,000 point data logger

Recommended Products For Greyline


Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline ISM 5.0 Insertion Magmeter
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline DFM 6.1 Doppler Flow Meter
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline DFS 5.1 Doppler Flow Switch
Greyline LIT25 Level Indicating Transmitter
Greyline DLT 2.0 Differential Level Transmitter
Stauff RALU218 COLLARE A COPPIA D.18
American Industrial AA-1224-TP Heat Exchanger
Marzocchi GHM2A-R-25-E2 Gear Motor
Vogel MKU1-13AD02000 924 Single Line Pump
Holthausen ESW Small-Transmitter
Stenflex Type A-3 DN 32 Expansion Joint
Tinker Rasor SR-2 Soil Resistivity Meter
Hengstler RI58-O/1000AK.42TB-F0 Encoder
Bürkert 20091617 Valve
Aron ADB3E03EK003 ADB3E Cetop 03 valve 4/2 AC Coil
MBS MLW 139 19 16 1 6000 Sanitary Mixflo Multitube
Hengstler AC58/1212EK.42PBA-A1-F Absolute Encoder
Senseca NM-007HP-959075 Level Switch
Hengstler RI58-O/10000AK.72RB-F0 Encoder
Atos HR-003 30 Check Valve
American Industrial UCS-1260 Heat Exchanger
Hengstler RI58-O/1000EK.41IB Encoder
Eaton Vickers (Danfoss) DG4V30BMUH760 Solenoid Operated Directional Valves
Samson 6111-0020111410110000.00 Var-ID 1011525 Converter
Sensitron S3665R507A Gas Detector
MBS MLD 100 4 28 1 2000 Mixflo Multitube Demontable Heat Exchanger
Parker 15P110QHVPSKX2 Duplex Filter
Metalwork FIL 400 1 1/4 50 RMSA 6280003U
Faggiolati X618R2C1-S100LA5 Pump