im-tek.com

Dynisco ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors

Dynisco

Product Code: ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco PT160-4M-M11 Pressure Sensors
Dynisco 2291NA48K11BUTTACAZZ Pressure Sensors
Dynisco PT462F-1/2-10M-6/18 Pressure Sensors
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco PT415D-5M-6-B314-B173 Pressure Sensors
Dynisco PT462E-5M6/18 Pressure Sensors
Dynisco PT130-3M Pressure Sensors
Dynisco PT160-4M-M11 Pressure Sensors
Dynisco PT 160-4M-H11 Pressure Sensors
Dynisco MDT 462F 10M 6/18 Melt Pressure Transmitters
Dynisco TDA463-1/2-3,5C-20/46 Pressure Sensors
Dynisco ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers
Dynisco MDT463H-1/2-5C-15/46 Pressure Sensors
Dynisco PT4624-35MPA-6/18 Pressure Sensors
Dynisco ECHO-MV3-MPA Melt Pressure Transducers
Dynisco ECHO-MA4-BAR-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco MDT462F-1-2-3,5C-15-46 Melt Pressure Transmitters
Sitema KFH 25 KFH 025 71 Locking Unit
Woerner VPA-I Progressive distributor
Faulhaber 1218S006B Brushless DC-Servomotor
Scherzinger 5020-210-DM-300-2 Cast iron pump with magnetic coupling 5020
Air Dimensions R221 R-Series Dia-Vac® Pump Double Head Hazardous Area
ETP HYDRO-GRIP BI-1 1/2"/50-85 Sleeve
MBS MLD 88 4 20 1 2000 Mixflo Multitube Demontable Heat Exchanger
Spirax Sarco M33F ISO Ball Valve
Hengstler AX70/0010EK.72DPA-F0 Absolute Encoder
Negele TFP Series Temperature Sensor With Thread M12
Megger DDA-16 Digital Data Acquisition Instrumentation and Control System
Hengstler AD36/1213EF.0CSCB Absolute Encoder
Control Techniques 4TMF90L-4,1/5KW,1410PRM Encoder
Rhomberg SC130 Liquid Level Relay - 11-pin
Foxboro 244LD-SI3J3LNMH1C4-HML2368 Intelligent Buoyancy Transmitter
Wilkerson L30-06-000 - LUBRICATOR,3/4
Franz Kessler SMS 100-617.488 Turning Spindles
KSB BPD242/05A+UMAIF 150-6/22 2.5 SQMM DOL Pump
Micro Detectors BX80A/1P-0H Area Sensor
Honsberg TZ1-015GR006 Flow Switch
Habasit TC-35/30ER Power Transmission Belt
KSB MCPK125-100-160 EC MP2 A Pump
JUMO DTR-08Q/1-001-59-0
Goldammer G3/4 ‘’-T-L200-T2-VA-2M12-TF70Ö-4-20mA Indicator