im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco PT160-5C Pressure Sensors
Dynisco MDA462-1/2-3.5C-15/46 Pressure Sensors
Dynisco MDT 462F-1/2-3,5C-32/46A Melt Pressure Transmitters
Dynisco PT462E-1/2-3M-6/30 Pressure Sensors
Dynisco 22420000109 Pressure Sensors
Dynisco SPX 4222 N-A-00-B-17-CE-DD-A-AF-ZZ-GC8 Pressure Sensors
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco DYMT-S-M18-J-7-15-G-2M-F13 Melt Temperature Probe
Dynisco PT462E-1/2-15M-12/18 Pressure Sensors
Dynisco 224200000142 Pressure Sensors
Dynisco SPX4622-S-A-00-B-21-DP-DD-A-AA-ZZ Pressure Sensors
Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Dynisco UPR900-4-0-1-1-1-0-0-0 Process Indicator
Dynisco TPT463E-15M-6/18 Pressure Sensors
Dynisco PT-242FM-50 Pressure Sensors
Dynisco DYMT-F-1/2-PT100/3-0-32-G Melt Temperature Probe
Dynisco MDT462F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco ATC990202011010 Process Controller
T-T Electric LAK 2080B DC Motor
PSP Pohony EBB special brake
Megger OTS80AF Laboratory Oil Tester
Grundfos NK 150-400/394 AA1F1AESBAQEWW3 Pump
Emotron FDU48-365-20 Drive
Adalet XCE-101008 Explosion Proof Control Enclosures
Habasit WVT-185 Food Belt
MBS MLD 76 4 20 1 3000 Mixflo Multitube Demontable Heat Exchanger
Trafag 12110400K Protection tubes for direct mounting
Labom CB1020-B1055-H2 Pressure Transmitter
Herma FS 03 Taster Label Sensor
Faulhaber HXM3-64 Series Encoder
Hoyer MS Series IE1/8 Pol Marine Motor
Gelbau 252.00Z 3002.5200Z Housing type A
Eaton DILMC25-10-EA Contactor
KWD ZAKU-N A 100000 Coupling
Gemü Gemü 807R25D 72214 155 1600 Variable Area Flowmeter
Hengstler RI59-O/1024EQ.7ARB-K0 Encoder
Grundfos CR 1S-30 A-FGJ-A-E-HQQE Multi Stage Pump
Mp Filtri MR6303A10A Filter
Grundfos NK 150-500/489 AA1F1AESBAQEYW3 Pump
Sensitron S4008AM Sensor Head
Marzocchi ALP2-D13 Pump
Koso 101NN Differential Pressure Switches and Transmitters