im-tek.com

Greyline DFS 5.1 Doppler Flow Switch

Greyline

Product Code: DFS 5.1
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline DFS 5.1 Doppler Flow Switch

Flow Control from the Outside of Metal or Plastic Pipes5 amp DPDT Control RelayAdjustable ON/OFF Set-PointsHi or Lo Flow Alarm ModeAdjustable Time DelayRelay Status LEDFlow Rate LED bar graphFlow Switch With Non-Contacting SensorControl Flow from outside a pipe. Recommended for "difficult liquids" including wastewater, cooling water, slurries, sludge, chemicals, viscous liquids and abrasives. The Greyline DFS 5.1 is ideal for pump protection or to activate flow/no-flow alarms.Easy to CalibrateThe DFS 5.1 control relay can be set to turn ON and OFF at any flow rate between 0.25 and 10 ft/sec (0.075 to 3 m/sec). Insert two links for separate ON/OFF set points or just one link for a Hi or Lo flow alarm. Set the relay actuation time delay from 0 to 80 seconds.A bright LED indicator shows the relay state and a LED bargraph shows the flow rate. Electronics are housed in a watertight polycarbonate wall-mount enclosure.The clamp-on ultrasonic sensor mounts on the outside of metal or platic pipes without cutting the pipe or shutting down flow. It works on any pipe diameter 1/2" (12.5 mm) or larger and installs in minutes. There are no moving parts and no maintenance is required. The shielded sensor cable length is 20 ft. (6 m) and can be extended up to 500 ft. (152 m) with an optional Junction Box.DOPPLER FLOW SWITCH SPECIFICATIONSSCOPE: This specification covers a non-intrusive, ultrasonic Doppler-type flow switch as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for flow control at adjustable flow velocities.A. PERFORMANCE SPECIFICATIONSThe flow switch shall operate with a clamp-on ultrasonic sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) diameter.Shall operate on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.The control ON and OFF set-points shall be independently adjustable for flow rates between 0.25 ft/sec (0.076 m/sec) and 10 ft/sec (3 m/sec).B. TRANSDUCER (SENSING ELEMENT)The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi.Manufacturer's recommended coupling compound and stainless steel pipe clamp shall be included.Shall connect to separate electronics housing with 20 ft (6m) shielded coaxial cable pair with waterproof, potted bond to the Sensor head.Shall be capable of extending sensor cable up to 500 ft (152m) without adjustment and with no reduction in performance or signal strength.C. ELECTRONICS/CONTROLLERShall be housed in a wall-mount watertight, dust tight NEMA4X (IP 66) polycarbonate enclosure with a gasketed shatter proof window.Have a power input of 100–240VAC 50-60Hz (±10%), 2.0 W Max.Shall include one 5 ampere DPDT control relay.Shall operate in Hi or Lo alarm mode, or with separate ON/OFF set points individually adjustable between 0.25 and 10 ft/sec (0.076 to 3 m/sec).The controller shall include an indicator LED to display relay status and a LED bargraph to display flow rate.The controller shall include relay time delay adjustment from 0 to 80 seconds.The flow switch electronics/controller shall operate at temperatures from -10° to 140°F (-23° to 60°C).Shall be designed for maximum RFI rejection.D. OPTIONAL FEATURES FOR INSERTION IN SPECIFICATION AS REQUIREDHave a power input of 12-24VDC (±10%), 3.0 W Max.Have 50 ft (15 m) continuous length shielded coaxial pair sensor cable.Have 100 ft (30 m) continuous length shielded coaxial pair sensor cable.Have a Cable Junction Box and up to 500 ft (152 m) total length cable that shall be shielded coaxial pair and installed in conduit for mechanical protection.E. MANUFACTURERThe flow switch shall be a Model DFS 5.1 Doppler Flow Switch as manufactured by Greyline Instruments Inc., and warranted against defects in materials and workmanship for one year.

Recommended Products For Greyline


Greyline DLT 2.0 Differential Level Transmitter
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline DFS 5.1 Doppler Flow Switch
Greyline DFM 6.1 Doppler Flow Meter
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline LIT25 Level Indicating Transmitter
Greyline ISM 5.0 Insertion Magmeter
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline AVFM 6.1 Area-Velocity Flow Meter
Goldammer NTR 50-SR45-T2-A-FE-L370-01-L1/250/S-T70Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Kadant 9940173/0003 SX Rotary Joint
Goldammer IN-GB-100D NR 1/2″-3/4″-M20-M24-Desina Level Regulator for Tank Insert
Aignep 251 MALE PLUG
Hengstler RI59-O/1250EQ.7AKA Encoder
Meggitt Vibro-Meter VMD-TSW101-M1-H05-WW 007-Y02 TSW 101M1 Transmitter
Scherzinger 4050-710-B-DM-37-2-Exe Titanium Gear Pumps 4050
Alfa Laval LKHM-114/163 11.0KW 50HZ 230D/400-415Y SMS FSS C/SIC EPDM BLASTED SCREW Pump
Alfa Laval 9611442191 VALVE LKB 25/1
Dropsa DL 32 oil Injector
Stahl G150/1-0200-0300-150-3321 Terminal Box
Böhmer FSK V 025.040 Ball Valve
Eaton DSF 6005 Duplex Filter
Tokimec TGMX2-3, 50 series Pressure Reducing Valves
Winsmith 300D Double Reduction Worm Gear
Gemü 600 8M5A Diaphragm
Honeywell UDC3200 Universal Digital Controller
Enerpac P392FP Hydraulic Foot Pump
Italvibras CDX 10/40-G/D 602315 Explosion Proof-electric Vibrator
Atos DHE-0717-X 24DC Valve With Coil
Scherzinger 5030-210-DM-150-2-Exd Stainless Steel Gear Pumps 5030
Gefran WPA-S-B-050-G-4 000XX11X00X0XX Transducer
Eaton Vickers (Danfoss) DG4V33CMUH7G0 Valve
Parker DF25110NEVT1KG121 Duplex Filter