im-tek.com

Greyline ISM 5.0 Insertion Magmeter

Greyline

Product Code: ISM 5.0
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline ISM 5.0 Insertion Magmeter

electromagnetic with no moving partssimplified hot tap insertion designinstalls in 3-72" (80-1800 mm) diameter pipesselectable 4-20mA, 0-5V or 0-10V output0-500Hz frequency outputscalable pulse outputAccurate, Low Cost Alternative to Full-bore Magnetic Flow MetersMeasure flow of water and conductive liquids in full pipes from 3 to 72" (80 to 1800 mm) diameter.The ISM 5.0 dual pair electrode sensor inserts through a tap in the pipe wall. It can be easily installed in new pipe systems or by hot tap in pressurized pipes with flowing liquids. There are no moving parts so obstruction to flow and pressure drop is minimal. Installation through a full port ball valve allows easy retraction and reinsertion without shutting down flow. The insertion depth is adjustable according to the pipe diameter and an insertion depth gauge is supplied with each flowmeter. The optional Installation Hardware Kit includes a branch outlet, close nipple and full port 1” isolation valve. The ISM 5.0 Insertion Magmeter senses flow using a low maintenance electromagnetic design with no moving parts. The dual-electrode sensor and continuous auto-zero function provides high accuracy – even at low flow rates. State-of-the-art electronics and patented design features help maintain its NIST traceable accuracy over time.No Onsite Calibration RequiredBased on your pipe type and size, liquid and flow rate each ISM 5.0 Insertion Magmeter is shipped from our factory configured for your application and ready to install. Connect the isolated 4-20mA output to control system or remote display, or use the relay pulse output.Installs through a Ball Valve into the pipeHow It WorksThe ISM 5.0 Insertion Magmeter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the ISM flow meter, electrodes measure the voltage increase to accurately calculate flow. Four electrodes measure the induced voltage on opposite sides of the sensor. The voltage readings are sampled and averaged.The ISM 5.0 Insertion Magmeter measures flow of electrically conductive liquids (20 µS/cm or greater) in full pipes. For proper measurement on plastic pipes the electromagnetic flow meter requires electrical grounding by connection to grounding rings or ground probes inserted into the pipe. Readings are not affected by the fluid temperature, pressure or viscosity.INSERTION MAGMETER SPECIFICATIONSProvide a Greyline ISM 5.0 Insertion Magmeter complete with all installation hardware necessary to enable insertion and removal of the meter without system shutdown. The flow meter shall be hand-insertable up to 400 psi. For installations in non-metallic pipe, install grounding rings or probes. Materials of construction for wetted metal components shall be 316 SS.  The flow meter shall average velocity readings from two sets of diametrically opposed electrodes.  Each flow meter shall be individually wet-calibrated against a primary volumetric standard that is accurate to within 0.1% and traceable to NIST*.  A certificate of calibration shall be provided with each flow meter. Accuracy shall be within ± 1% of rate from 2-20 ft/s. Overall turndown shall exceed 100:1.Output signals shall be completely isolated and shall consist of the following: (1) analog output; 4-20mA, 0-10V, or 0-5V jumper selectable, (1) scalable dry contact output for totalization, and (1) high resolution frequency output for use with peripheral devices.  ISM 5.0-B for Bi-directional applications shall provide additional contact outputs for direction and flow totalization in each direction. Each flow meter shall be certified to NSF Standards and covered by the manufacturer’s two-year warranty.* National Institute of Standards and TechnologyOptional Flow DisplayD-100 Series Display Module for network interface and local / remote indication of flow rate and total.

Recommended Products For Greyline


Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline LIT25 Level Indicating Transmitter
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline ISM 5.0 Insertion Magmeter
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline DFM 6.1 Doppler Flow Meter
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline DFS 5.1 Doppler Flow Switch
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline DLT 2.0 Differential Level Transmitter
Stenflex A-2/A-4/1-D15, A-2/A-4/2-D15 Compansator
Atos DKZE-A-171-L5/6 Porpotional Valve
MBS MLW 114 7 32 1 1000 Sanitary Mixflo Multitube
American Industrial UCN-1748 Heat Exchanger
Apollo 262.000.2010 Inner Guide Profile
SKF W 618/1.5 R Deep Groove Ball Bearings
Alfa Laval LKH-40/235 22.0KW 50HZ 230D/400-415Y SMS SSS C/SIC EPDM BLASTED SCREW 9613394854 Pump
Goulds 3700 API 610 (OH2) API 610 Process Pump
Servomech MA 25 Mod B Screw Jack
Habasit TMBE02470 Belt
Heidenhain 521289-53 Incremental Encoder
Greisinger GPB3300 Barometer
Tecsis EZE11 Strain Gauge Amplifier
Apv DN 65 H16071 Disc For Butterfly Valve
Hengstler AC58/1214AK.42SGA Absolute Encoder
Vulcanic 2048-06 Screw Plug Immersion Heater
Micro Detectors CV/RB6-20ME Photoelectric Sensor
VIMARC CFPZ 200-4 Vibrator motors
Armatury C61.4 113 TYP 141 Butterfly valve double-lever
Eckerle EIPH6-RB - SAE shaft end toothed with through drive
Faggiolati Gnasher 6T 400v Pump
Edur NUB600F105-3500 Single Stage Close-Coupled Pump
Atos LIDEW-2 50 Cartridge Cover
Dynisco PT462-35MPA-6/18 Pressure Sensors