im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Dynisco DYMT-S-M18-PT100/4-15-15-G Melt Temperature Probe
Dynisco TPT4634-35MPA-12/18-SIL2 Pressure Sensors
Dynisco MDA462-M18-3,5C-15/46 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensor
Dynisco PT4624-10M-6/18-SIL2 Pressure Sensors
Dynisco MDA460-1/2-1M-15 Pressure Sensors
Dynisco TDT463F-1/2-3,5C-15/46-A Pressure Sensors
Dynisco PT415D-5M-6-B314-B173 Pressure Sensors
Dynisco TPT463E-5M-6/18 Pressure Sensors
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco MDT462F-1/2-2C-15/46 Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco 463F0002 Pressure Transmitter
Dynisco PT4624-5CB-6/18A Pressure Sensors
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco MDT 462F-1/2-3,5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco UPR900-2-1-0-0-0-0-0-0 Process Indicator
Vogel 351-8VS-40000-00 Single-line - Piston Metering Device
Chiaravalli CHS3 Serial:006613 Reducer
Marzocchi 1PD 3.3 Gear Pump
Metalwork 3483034U FR 200 1/4 5 012 SAC
Stenflex Type AR-2 DN 50 Expansion Joint
Bollfilter 6530423 Filter Bowl - Spare Part
Felm F3X 315XC-6 Motor
Intorq BFK458-06-16211991 Spring-applied Brakes
Atlas Copco 0663210322 O-ring 264x3
Habasit PMTEF-BE Belt
Prominent 732424 Electronic Card
Trimod-Besta 2383 Test Lever
SKF M12X1 Connector With Cable
Asco Numatics 082SS63AMG00061 Valve
Stauff 1910000179 DRV-08-B-G 1 / 4 BSP Throttle check valve
Friedrich FHE 2000-6-8.0 Vibrator Motor with Stainless Steel End Cover FHE-Type
Greisinger GEG91 Handle
Rhomberg SC100 Relay for Resistive Sensor
Winsmith 10MCTT Triple Reduction Motorized and Gearmotor Speed Reducer
Thytronic T80 Toroidal Transformer
Sauter BUE050F200 3 Way PN10/16 DN50 KVS 40 Flanged Valve
Vulcanic 3214-04 Screw Plug Immersion Heater
Samson 3755-21300000000000.00 2468442 Valve
Atlas Copco 1092 2001 50 V-belt