im-tek.com

Dynisco ECHO-MV3-MPA-R21-UNF-HIR-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA-R21-UNF-HIR-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA-R21-UNF-HIR-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco PT4626-1/2-35MPA-6/18 Pressure Sensors
Dynisco MDT462F-M18-3.5C-50/46-A Melt Pressure Transmitters
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDA462-1/2-5C-15/46-B171 Pressure Sensors
Dynisco PT-242FM-35MPA-6/30 Pressure Sensors
Dynisco DYMT-F-1/2-PT100/4-0-15-G-2M Melt Temperature Probe
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco ATC 770-0-3-3 Process Controller
Dynisco ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer
Dynisco ATC990-4-1-1-1-0-1-0-0-0 Process Controller
Dynisco 224200000142 Pressure Sensors
Dynisco MDA460-1M-15 Pressure Sensors
Dynisco PT462E-7CB-6/18 Pressure Sensors
Dynisco PT160-5C Pressure Sensors
Dynisco MDT422F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco ATC990400110000 Process Controller
Dynisco 2291SA48K20BSMMAACAK Pressure Sensors
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
SKF 6015-2Z Bearing
Alfa Laval 9612075229 VALVE LKB-2 DN25 DIN M/M FPM 304L
Metalwork 3471004U APR 200 1/4 SOLENOID CNOMO CONTROL
Air Dimensions R181 R-Series Heated Head Dia-Vac® Pump
Adler EVJ32 24DC SOLENOID VALVES
Goyen RCA3D2 24V Solenoid Valve
KSB ETN 050-032-2501GI CP1CGA2 B Pump
Italvibras MVSI 075/26000-S90-TS 602535 Electric Vibrator with Split Cover
Satron VDU5 Pressure Transmitter
Vulcanic 2389-53 Flange Immersion Heater
Eaton 104-1034-010 Motor
Faulhaber 2233T018S DC-Micromotor
Adler ASL 322 LIMIT SWITCH BOX
Festo DSBC-32-70-PPVA-N3 Iso Cylinder Festo DSBC-32-70-PPVA-N3 Iso Cylinder
Hengstler RI58-O/10000AK.42KB-K0 Encoder
Edur SUB500C150L-2900 Self-Priming Centrifugal Pump
SKF W 618/4 R Deep Groove Ball Bearing
Vogel MKU1-13AB11000 428 Single Line Pump
Meggitt Vibro-Meter TQ902 Proximity Sensor
Stahl 8146/5-V11d06-00-0000-0 Load Disconnect and Manual Transfer Switch
Nippon TOP-N340/FA Trochoid® Pumps
Schorch BN7 357M Three-phase-motor
PIV C-X3H-28-R 1 1-V11-25 Single Screw Extruder Drives
Heidenhain 533631-03 Encoder Cable 3 Meters