Nom du Produit: ESN Type 8532/8533 Cable Monitoring Device
Marque: ESN
Code Produit: Type 8532/8533
Mots-clés: ESN
ESN Type 8532/8533 Monitoring
ESN Type Cable Monitoring Device
ESN Cable
ESN Cable Device
Device
Monitoring Device
ESN Monitoring Device
Monitoring
ESN Device
Type 8532/8533 Cable
Cable Monitoring
ESN Type Cable Device
8532/8533 Monitoring
ESN Type 8532/8533 Cable Device
ESN Type
Cable Monitoring
8532/8533 Monitoring
ESN Type 8532/8533 Cable
Type Monitoring
ESN Type 8532/8533 Monitoring Device
Cable Monitoring Device
Êtes-vous intéressé par le produit ESN Type 8532/8533 Cable Monitoring Device du fabricant ESN avec le code Type 8532/8533? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour ESN Type 8532/8533 Cable Monitoring Device de notre équipe de support en direct maintenant!
The cable monitoring device is suitable for monitoring cable systems for supplying the traction current to direct current railways and O-buses with rated voltages of up to 750 V (other voltages on request). Material Housing: ABS / terminals: polycar- bonate Fastening 2 screws M4 or M5, or standard support rail DIN EN 50022 Ambient temp. 20°C to +60°C Auxiliary voltage DC 24 – 60 V (via internal switching- mode power supply) Power consumption approx. 5 W (incl. display) Fuses 0.5 A medium-slow acting (external) Traction voltage Positive potential at contact line Un DC 500-900 V ? 8532 -- Negative potential at contact line ? 8533 -- Power consumption approx. 1 W Fuse approx. 35 mA medium-slow acting (external) Shield voltage approx. 40 V (at DC 750 V) Switching points adjustable insulation defects Conductor-shield 350 – 1500 k (I) Shield-earth 10 – 400 k (E) Switching on delay auxiliary voltage approx. 10 s traction voltage approx. 2 s Response delay „I“ internal fault approx. 2 s, „E“ earth fault approx. 15 s Test buttons separate for „I“ internal fault and „E“ earth fault Outputs 1 potential-free closing contact each operation = idle current operation earth fault = working current mode 2 separate potential-free closing contacts internal fault = working current mode Switching AC 11 as per VDE 660 T2 Voltage max. DC 120 V / AC 250 V Current max. 5 A at AC 230 V Power max. 120 W / 1250 VA Version without shield interruption monito- ring ? 853- 00 with shield interruption monitoring (as “I“ internal fault) 853- 10 with shield interruption monitoring (as “E“ earth fault) 853- 20 Displays (integrated) by means of LEDs „operation“ 0 yellow, „I and E fault“ = red