im-tek.com

Greyline DFS 5.1 Doppler Flow Switch

Greyline

Product Code: DFS 5.1
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline DFS 5.1 Doppler Flow Switch

Flow Control from the Outside of Metal or Plastic Pipes5 amp DPDT Control RelayAdjustable ON/OFF Set-PointsHi or Lo Flow Alarm ModeAdjustable Time DelayRelay Status LEDFlow Rate LED bar graphFlow Switch With Non-Contacting SensorControl Flow from outside a pipe. Recommended for "difficult liquids" including wastewater, cooling water, slurries, sludge, chemicals, viscous liquids and abrasives. The Greyline DFS 5.1 is ideal for pump protection or to activate flow/no-flow alarms.Easy to CalibrateThe DFS 5.1 control relay can be set to turn ON and OFF at any flow rate between 0.25 and 10 ft/sec (0.075 to 3 m/sec). Insert two links for separate ON/OFF set points or just one link for a Hi or Lo flow alarm. Set the relay actuation time delay from 0 to 80 seconds.A bright LED indicator shows the relay state and a LED bargraph shows the flow rate. Electronics are housed in a watertight polycarbonate wall-mount enclosure.The clamp-on ultrasonic sensor mounts on the outside of metal or platic pipes without cutting the pipe or shutting down flow. It works on any pipe diameter 1/2" (12.5 mm) or larger and installs in minutes. There are no moving parts and no maintenance is required. The shielded sensor cable length is 20 ft. (6 m) and can be extended up to 500 ft. (152 m) with an optional Junction Box.DOPPLER FLOW SWITCH SPECIFICATIONSSCOPE: This specification covers a non-intrusive, ultrasonic Doppler-type flow switch as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for flow control at adjustable flow velocities.A. PERFORMANCE SPECIFICATIONSThe flow switch shall operate with a clamp-on ultrasonic sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) diameter.Shall operate on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.The control ON and OFF set-points shall be independently adjustable for flow rates between 0.25 ft/sec (0.076 m/sec) and 10 ft/sec (3 m/sec).B. TRANSDUCER (SENSING ELEMENT)The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi.Manufacturer's recommended coupling compound and stainless steel pipe clamp shall be included.Shall connect to separate electronics housing with 20 ft (6m) shielded coaxial cable pair with waterproof, potted bond to the Sensor head.Shall be capable of extending sensor cable up to 500 ft (152m) without adjustment and with no reduction in performance or signal strength.C. ELECTRONICS/CONTROLLERShall be housed in a wall-mount watertight, dust tight NEMA4X (IP 66) polycarbonate enclosure with a gasketed shatter proof window.Have a power input of 100–240VAC 50-60Hz (±10%), 2.0 W Max.Shall include one 5 ampere DPDT control relay.Shall operate in Hi or Lo alarm mode, or with separate ON/OFF set points individually adjustable between 0.25 and 10 ft/sec (0.076 to 3 m/sec).The controller shall include an indicator LED to display relay status and a LED bargraph to display flow rate.The controller shall include relay time delay adjustment from 0 to 80 seconds.The flow switch electronics/controller shall operate at temperatures from -10° to 140°F (-23° to 60°C).Shall be designed for maximum RFI rejection.D. OPTIONAL FEATURES FOR INSERTION IN SPECIFICATION AS REQUIREDHave a power input of 12-24VDC (±10%), 3.0 W Max.Have 50 ft (15 m) continuous length shielded coaxial pair sensor cable.Have 100 ft (30 m) continuous length shielded coaxial pair sensor cable.Have a Cable Junction Box and up to 500 ft (152 m) total length cable that shall be shielded coaxial pair and installed in conduit for mechanical protection.E. MANUFACTURERThe flow switch shall be a Model DFS 5.1 Doppler Flow Switch as manufactured by Greyline Instruments Inc., and warranted against defects in materials and workmanship for one year.

Recommended Products For Greyline


Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline LIT25 Level Indicating Transmitter
Greyline DFS 5.1 Doppler Flow Switch
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline DFM 6.1 Doppler Flow Meter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline ISM 5.0 Insertion Magmeter
Greyline DLT 2.0 Differential Level Transmitter
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline TTFM 6.1 Transit Time Flow Meter
Grundfos NK 100-280/194 AA1F1S3ESBQQEHW5 Pump
Scherzinger 4050-710-B-DM-55-2-Exd Titanium Gear Pumps 4050
HFB GUF 222 Plummer Block Housing
Grundfos NK 200-400/280 AA1F1AESBAQESW3 Pump
Dynisco SPX4622-S-A-00-B-21-DP-DD-A-AA-ZZ Pressure Sensors
Aerzen 119193000 Bearing Cylinder Roller Nu 216-e-jp3.c3
Habasit NHM-10ESBV-E3 Light Conveyor Belt
Senseca LF4043-C0,5-300-00 Conductivity Cell Lf4043
KWD TK-N-A-MEM 800 - 65 H7 - 70 H7 x 140 - KWN 29000 Coupling
Mahle Pi 2145 PS 3 77680184 Duplex Filter
Officine Orobiche IVF Series-SBE 150 Visual Flow Indicator
Atlas Copco 1837031035 Kit Mk5s Touch Lpwa - No I/o U
KSB MCPK100-065-160 EC MP2 A Pump
Bardiani BEBACC065BEBV Manuel Valve
Atlas Copco 0502 1100 83 Bearing Ball
Alfa Laval 9613327186 UNIQUE SSV DN-50 300 W 0.8/BLASTED FPM SHUT OFF NC
Pizzato VF L52-R24 Lever
Wandfluh AMW4D61 Valve
Vulcanic 3114-30 Screw Plug Immersion Heater
Abo Valve Swing check valves Series 800
Vogel 341-200-20000-00 Single-line - Piston Metering Device
Alfa Laval 9612628132 VALVE LKB 38/1½
Wilkerson F18-03SK-00 Particulate Filter
Topworx 76-13567H2 - SPDT, End Sensing, CSA GP, 36Inch PEEK Leads, 316 Stainless Steel, Model 76 GO Switch