im-tek.com

Greyline ISM 5.0 Insertion Magmeter

Greyline

Product Code: ISM 5.0
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline ISM 5.0 Insertion Magmeter

electromagnetic with no moving partssimplified hot tap insertion designinstalls in 3-72" (80-1800 mm) diameter pipesselectable 4-20mA, 0-5V or 0-10V output0-500Hz frequency outputscalable pulse outputAccurate, Low Cost Alternative to Full-bore Magnetic Flow MetersMeasure flow of water and conductive liquids in full pipes from 3 to 72" (80 to 1800 mm) diameter.The ISM 5.0 dual pair electrode sensor inserts through a tap in the pipe wall. It can be easily installed in new pipe systems or by hot tap in pressurized pipes with flowing liquids. There are no moving parts so obstruction to flow and pressure drop is minimal. Installation through a full port ball valve allows easy retraction and reinsertion without shutting down flow. The insertion depth is adjustable according to the pipe diameter and an insertion depth gauge is supplied with each flowmeter. The optional Installation Hardware Kit includes a branch outlet, close nipple and full port 1” isolation valve. The ISM 5.0 Insertion Magmeter senses flow using a low maintenance electromagnetic design with no moving parts. The dual-electrode sensor and continuous auto-zero function provides high accuracy – even at low flow rates. State-of-the-art electronics and patented design features help maintain its NIST traceable accuracy over time.No Onsite Calibration RequiredBased on your pipe type and size, liquid and flow rate each ISM 5.0 Insertion Magmeter is shipped from our factory configured for your application and ready to install. Connect the isolated 4-20mA output to control system or remote display, or use the relay pulse output.Installs through a Ball Valve into the pipeHow It WorksThe ISM 5.0 Insertion Magmeter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the ISM flow meter, electrodes measure the voltage increase to accurately calculate flow. Four electrodes measure the induced voltage on opposite sides of the sensor. The voltage readings are sampled and averaged.The ISM 5.0 Insertion Magmeter measures flow of electrically conductive liquids (20 µS/cm or greater) in full pipes. For proper measurement on plastic pipes the electromagnetic flow meter requires electrical grounding by connection to grounding rings or ground probes inserted into the pipe. Readings are not affected by the fluid temperature, pressure or viscosity.INSERTION MAGMETER SPECIFICATIONSProvide a Greyline ISM 5.0 Insertion Magmeter complete with all installation hardware necessary to enable insertion and removal of the meter without system shutdown. The flow meter shall be hand-insertable up to 400 psi. For installations in non-metallic pipe, install grounding rings or probes. Materials of construction for wetted metal components shall be 316 SS.  The flow meter shall average velocity readings from two sets of diametrically opposed electrodes.  Each flow meter shall be individually wet-calibrated against a primary volumetric standard that is accurate to within 0.1% and traceable to NIST*.  A certificate of calibration shall be provided with each flow meter. Accuracy shall be within ± 1% of rate from 2-20 ft/s. Overall turndown shall exceed 100:1.Output signals shall be completely isolated and shall consist of the following: (1) analog output; 4-20mA, 0-10V, or 0-5V jumper selectable, (1) scalable dry contact output for totalization, and (1) high resolution frequency output for use with peripheral devices.  ISM 5.0-B for Bi-directional applications shall provide additional contact outputs for direction and flow totalization in each direction. Each flow meter shall be certified to NSF Standards and covered by the manufacturer’s two-year warranty.* National Institute of Standards and TechnologyOptional Flow DisplayD-100 Series Display Module for network interface and local / remote indication of flow rate and total.

Recommended Products For Greyline


Greyline DLT 2.0 Differential Level Transmitter
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline ISM 5.0 Insertion Magmeter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline DFM 6.1 Doppler Flow Meter
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline DFS 5.1 Doppler Flow Switch
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline LIT25 Level Indicating Transmitter
Greyline AVFM 6.1 Area-Velocity Flow Meter
SKF 22324 CCJA/W33VA405 Bearing
Steimel SF 6/132 RD - VLF Gear Pump
Scherzinger 5020-130-DM-25-8 Cast iron pump with magnetic coupling 5020
Elcis 72 I05 - Series for motors
KSB UPAC 4-002/18 -CCRBV-BSN 4T-52 Pump
KSB BPN374/03+HBC 413 10SQMM S.D. Pump
Knf NPK 09 AC Swing Piston Vacuum Pump
American Industrial UCN-2036 Heat Exchanger
Edur NUB600F128-2900 Single Stage Close-Coupled Pump
Roemheld Artikel-Nr. 0155400 Bearing Block
Grundfos NK 125-200/196-166 BA1F2AESBAQEUW1 Pump
Faulhaber 17/1 1367:1 Planetary Gearhead
Dropsa 8X19 L.1200 Flex
American Industrial FBF-1636-FP Heat Exchanger
MAC DPB-DEWJ-1JJ/EQ36 Solenoid Valve
Topworx 7LG-13527A3 - SPDT, End Sensing, CSA GP, Green LED, 72Inch Lead Wires, 303 Stainless Steel, Model 7L BriteLite GO Switch
Scherzinger 5030-210-DM-75-2 Stainless Steel Gear Pumps 5030
Adler APM 287 PNEUMATIC ACTUATORS
Habasit NAS-40EHAV-S2 Belt
Barksdale EPD1S, EPD1H Series Low Cost Differential Pressure Switch
Chiaravalli CH06 F24 Conveyor Gearbox
Barksdale P1H Series Dia-Seal Piston
Sumitomo Drive DP 1000 COMPOWER® Planetary Gear Reducer
Lamtec 663R0932T Programming Unit For CarboSen CT1