Nom du Produit: HEIDENHAIN LIC 411 FS Exposed Linear Encoder
Marque: HEIDENHAIN
Code Produit: LIC 411 FS
Mots-clés: HEIDENHAIN
HEIDENHAIN 411
HEIDENHAIN Linear Encoder
HEIDENHAIN Exposed Linear
411 Exposed Linear Encoder
LIC FS Encoder
LIC 411 Exposed
LIC Linear Encoder
HEIDENHAIN LIC 411 FS Encoder
HEIDENHAIN LIC
LIC FS Exposed Linear Encoder
HEIDENHAIN FS
Exposed Linear
HEIDENHAIN Exposed Linear
LIC 411 FS Linear
HEIDENHAIN LIC FS Exposed
FS Exposed Linear Encoder
HEIDENHAIN 411 Exposed Linear Encoder
LIC 411 Exposed Linear Encoder
LIC Exposed
HEIDENHAIN LIC 411 FS Linear
Exposed Linear Encoder
Êtes-vous intéressé par le produit HEIDENHAIN LIC 411 FS Exposed Linear Encoder du fabricant HEIDENHAIN avec le code LIC 411 FS? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour HEIDENHAIN LIC 411 FS Exposed Linear Encoder de notre équipe de support en direct maintenant!
ScaleLIC 4009Measuring standardCoefficient of linear expansionSteel scale tape with absolute and incremental METALLUR track?therm 10 · 10–6 K–1Accuracy grade*Baseline error±3 µm1), ±15 µm2)? ±0.750 µm/50 mm (typical)Measuring length (ML)* in mm 70 120 170 220 270 320 370 420 520 620 720 820920 3) 1020 3) 1220 3) 1420 3) 1620 3) 1820 3)Mass Scale tape Screw31 g/m< 1 gProtection 4)IP00Scanning head5)LIC 411InterfaceEnDat 2.2Ordering designationEnDat22Measuring step*0.01 µm (10 nm)0.005 µm (5 nm)0.001 µm (1 nm)Calculation time tcalClock frequency? 5 µs? 16 MHzFunctional safetyfor applications with up to SIL 2 as per EN 61508 (further basis for testing: EN 61800-5-2) Category 3, PL "d "as per EN ISO 13849-1:2015PFH? 20 · 10–9 (up to 6000 m above sea level)Safe position6)Encoder: ±550 µm (safety-relevant measuring step: SM = 220 µm);mechanical coupling: fault exclusions for the loosening of the scanning head and scale tape (see Functional safety)Traversing speed7)? 600 m/minInterpolation error±20 nmVibration 55 Hz to 2000 HzShock 11 ms? 200 m/s2 (EN 60068-2-6)? 200 m/s2 (EN 60068-2-27)Operating temperature–10 °C to 70 °CRelative air humidity? 93 % (at 40 °C/4d as per EN 60068-2-78); without condensationProtection EN 605294)IP67Mass Scanning head Connecting cable Connector? 18 g (without cable)20 g/mM12 coupling: 15 g; D-sub connector: 32 g* Please select when ordering1) Up to a measuring length of 1020 mm2) ±5 µm after linear length-error compensation in the subsequent electronics3) Additional measuring length only on steel mounting surface4) In the application, the device must be protected from contamination by solids and liquids. If necessary, use a suitable enclosure with a gasket and sealing air.5) For the electrical connection, look under LIC 411 without functional safety6) Further tolerances may apply in the subsequent electronics after position value comparison (contact the manufacturer of the subsequent electronics)7) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure