Nom du Produit: Hydropa WE6AHG-F4M Directional Control Valve
Marque: Hydropa
Code Produit: Hydropa WE6AHG-F4M
Mots-clés: Hydropa
Hydropa WE6AHG-F4M Directional Control
WE6AHG-F4M Valve
WE6AHG-F4M Directional Control Valve
Hydropa Directional Control
Hydropa Valve
WE6AHG-F4M Directional Control
Hydropa WE6AHG-F4M
Directional Control Valve
Hydropa WE6AHG-F4M Valve
Hydropa Directional Valve
Hydropa WE6AHG-F4M Directional
WE6AHG-F4M Control
Hydropa Control Valve
Hydropa WE6AHG-F4M Control
WE6AHG-F4M Control Valve
Control
Directional Control
Hydropa WE6AHG-F4M Control Valve
Article: WE6AHG-F4M
Hydropa WE6AHG-F4M
Êtes-vous intéressé par le produit Hydropa WE6AHG-F4M Directional Control Valve du fabricant Hydropa avec le code Hydropa WE6AHG-F4M? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Hydropa WE6AHG-F4M Directional Control Valve de notre équipe de support en direct maintenant!
FUNCTIONAL DESCRIPTIONThe directional control valve WE 10 AH essentially consists ofthe valve housing (1), the control piston (5) with twoCentering springs (4) and - depending on the application - one or twoElectromagnets (2 + 3) as actuators.Directional control valves with three switch positions have twoElectromagnets and two centering springs. Directional control valves withtwo switch positions are either with oneElectromagnet and a return spring or twoElectromagnets and a locking device.The control piston is activated by the electromagnets (2 + 3)(5) from its rest position to the desired end positionpushed. It gives the connection PComing pressure oil to port A or B free. AtInterruption of actuation will cause the spool inrested his rest position, or by resting in theheld respective end position.The electromagnets work with DC voltage. For theAC power supply are either inthe plug bases of the solenoid coil or in theDevice sockets (6 + 7) integrated rectifiers used.The device sockets can each be rotated 90 °.By loosening the fastening nut (8) you canturn the electromagnets (2 + 3) by 360 ° orswitch. The pressure-tight anchor tube is screwed in.This allows the solenoids to be opened without opening thepressure-tight room can be changed.In the event of a malfunction or a power failure, theControl piston by hand using the emergency manual operation (9)be adjusted.The surface of the valve body is phosphated andthe actuating magnets are galvanized