Nom du Produit: Hydropa WE6HY-F1M & Z6 RE - A Directional Control Valve
Marque: Hydropa
Code Produit: Hydropa WE6HY-F1M & Z6 RE - A
Mots-clés: Hydropa
Hydropa WE6HY-F1M & Z6 RE - A Control
& - A Valve
- Directional Control Valve
- A Control Valve
Hydropa & RE A Directional Control
Hydropa WE6HY-F1M A Directional Control
Hydropa & RE - A Directional Control
- A Directional Control Valve
Hydropa WE6HY-F1M & A Directional
& Z6 RE - A Control Valve
Hydropa WE6HY-F1M Z6 Control
WE6HY-F1M & A Directional
Hydropa WE6HY-F1M Z6 A Valve
Control Valve
& RE A Directional Valve
Hydropa WE6HY-F1M RE - A Directional Control Valve
WE6HY-F1M Z6 A Directional Control Valve
Hydropa WE6HY-F1M & Z6 RE - A Control Valve
Hydropa Z6 RE - A Directional Control Valve
Hydropa & RE - Directional Valve
Article: WE6HY-F1M & Z6 RE - A
Hydropa WE6HY-F1M & Z6 RE - A
Êtes-vous intéressé par le produit Hydropa WE6HY-F1M & Z6 RE - A Directional Control Valve du fabricant Hydropa avec le code Hydropa WE6HY-F1M & Z6 RE - A? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Hydropa WE6HY-F1M & Z6 RE - A Directional Control Valve de notre équipe de support en direct maintenant!
FUNCTIONAL DESCRIPTIONThe directional control valve WE 6 AH essentially consists ofthe valve housing (1), the control piston (5) with twoCentering springs (4) and - depending on the application - one or twoElectromagnets (2 + 3) as actuators.Directional control valves with three switch positions have twoElectromagnets and two centering springs. Directional control valves withtwo switch positions are either with oneElectromagnet and a return spring or twoElectromagnets and a locking device.The control piston is activated by the electromagnets (2 + 3)(5) from its rest position to the desired end positionpushed. It gives the connection PComing pressure oil to port A or B free. AtInterruption of actuation will cause the spool inrested his rest position, or by resting in theheld respective end position.The electromagnets work with DC voltage. For theAC power supply are either inthe plug bases of the solenoid coil or in theDevice sockets (6 + 7) integrated rectifiers used.The device sockets can each be rotated 90 °.By loosening the fastening nut (8) you canturn the electromagnets (2 + 3) by 360 ° orswitch. The pressure-tight anchor tube is screwed in.This allows the solenoids to be opened without opening thepressure-tight room can be changed.In the event of a malfunction or power failure, theControl piston by hand using the emergency manual operation (9)be adjusted.The surface of the valve body is phosphated andthe actuating magnets are galvanized.