Nom du Produit: Santerno ASAC1 Soft Starter
Marque: Santerno
Code Produit: ASAC1
Mots-clés: Santerno
Santerno Starter
Santerno ASAC1 Soft Starter
Santerno Soft Starter
ASAC1 Starter
Soft Starter
Santerno Soft
Santerno ASAC1 Starter
Starter
Santerno ASAC1 Soft
ASAC1 Starter
Santerno Soft Starter
Soft Starter
ASAC1 Soft
Santerno ASAC1
ASAC1 Soft
Starter
ASAC1 Soft Starter
Santerno Soft
Soft Starter
Êtes-vous intéressé par le produit Santerno ASAC1 Soft Starter du fabricant Santerno avec le code ASAC1? Contactez-nous maintenant et obtenez une offre. Imtek Engineering, le fournisseur d\'équipements industriels le plus rapide et le plus fiable au monde, vous offrira la meilleure offre!
Obtenez une offre par e-mail: info@im-tek.com
Obtenez une offre pour Santerno ASAC1 Soft Starter de notre équipe de support en direct maintenant!
Low voltage soft starters for three-phase asynchronous motors The ASAC is an advanced digital solution for the soft starting of motors ranging from 4.5kW to 160kW. Static soft starters ASAC by Santerno ensure reliable control of the soft start and stop of three-phase motors. The ASAC soft starter series comes with two product lines: ASAC-0 for motor soft starting and ASAC-1 for advanced control of complete starting of motor protection A high-tech solution fitting any industrial application – Compact size – Integrated bypass contactor. This allows the ASAC soft starters to be installed in a cabinet without any cooling system and with no need to install an external bypass contactor – Allowable max. overload up to 400% of the rated current – Degree of protection IP20/IP00 – N.6 signalling functions: Power Supply Loss, Soft Starter Ready, Soft Starter Fault, Motor Stopped, Motor Running at Max. Speed, Motor Starting/Stopping – Local reset – Models for different types of motor connections – Certification: CE, EAC, UL and RCM – Compatible with the “REMOTE DRIVE” software for the remote control of the deviceASAC-1 specifications for soft starting control N.8 Adjusting Modes: Motor Full Load Current (FLC), Current Ramp, Current Limit, Motor Trip Class, Soft Stopping duration, Excess Start Time, Phase Sequence Protection, Auxiliary Relay Function N.8 Trips: Power Section, Supply Frequency, Communications, Excess Start Time, Motor Overload, Motor Thermistor, Phase Imbalance, Phase Sequence N.3 Digital inputs: Start, Stop, Motor Thermal Probe N.2 Relay outputs: Line Contactor Relay, Programmable RelayMain options – Communications modules. Available communications protocols: Ethernet (Profinet, Modbus TCP, Ethernet/IP), Profibus, DeviceNet, Modbus RTU and USB. – Remote operator – Finger guard kit