| Scale | LIC 4009 |
| Measuring standardCoefficient of linear expansion | Steel scale tape with absolute and incremental METALLUR track?therm 10 · 10–6 K–1 |
| Accuracy grade*Baseline error | ±3 µm1), ±15 µm2)? ±0.750 µm/50 mm (typical) |
| Measuring length (ML)* in mm | 70 120 170 220 270 320 370 420 520 620 720 820920 3) 1020 3) 1220 3) 1420 3) 1620 3) 1820 3) |
| Mass Scale tape Screw | 31 g/m< 1 g |
| Protection 4) | IP00 |
| Scanning head5) | LIC 411 |
| Interface | EnDat 2.2 |
| Ordering designation | EnDat22 |
| Measuring step* | 0.01 µm (10 nm)0.005 µm (5 nm)0.001 µm (1 nm) |
| Calculation time tcalClock frequency | ? 5 µs? 16 MHz |
| Functional safetyfor applications with up to | SIL 2 as per EN 61508 (further basis for testing: EN 61800-5-2) Category 3, PL "d "as per EN ISO 13849-1:2015 |
| PFH | ? 20 · 10–9 (up to 6000 m above sea level) |
| Safe position6) | Encoder: ±550 µm (safety-relevant measuring step: SM = 220 µm); mechanical coupling: fault exclusions for the loosening of the scanning head and scale tape (see Functional safety) |
| Traversing speed7) | ? 600 m/min |
| Interpolation error | ±20 nm |
| Vibration 55 Hz to 2000 HzShock 11 ms | ? 200 m/s2 (EN 60068-2-6)? 200 m/s2 (EN 60068-2-27) |
| Operating temperature | –10 °C to 70 °C |
| Relative air humidity | ? 93 % (at 40 °C/4d as per EN 60068-2-78); without condensation |
| Protection EN 605294) | IP67 |
| Mass Scanning head Connecting cable Connector | ? 18 g (without cable)20 g/mM12 coupling: 15 g; D-sub connector: 32 g |
| * Please select when ordering1) Up to a measuring length of 1020 mm2) ±5 µm after linear length-error compensation in the subsequent electronics3) Additional measuring length only on steel mounting surface4) In the application, the device must be protected from contamination by solids and liquids. If necessary, use a suitable enclosure with a gasket and sealing air.5) For the electrical connection, look under LIC 411 without functional safety6) Further tolerances may apply in the subsequent electronics after position value comparison (contact the manufacturer of the subsequent electronics)7) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure | |