im-tek.com

Solberg 375P Polyester Replacement Filter

Solberg

Product Code: 375P Polyester
Brand: Solberg



GET OFFER: info@imtek.com.tr

Description for Solberg 375P Polyester Replacement Filter

Product DescriptionSolberg Polyester 375P Filter Element with PrefilterElement Rating: 1500 SCFMSurface Area ft2: 28Inner Diameter: 8″Outer Diameter: 11 3/4″Height: 14 1/2″Endcap: Galvanized metal endcaps with neoprene gaskets on open end(s)Filtration: Polyester, 99%+ removal efficiency to 5 micronTemp (continuous): min -26°F (-15°C), max 220°F (104°C)Filter change out differential: 15-20″ H2O over initial Δ PSolberg Filter Element FeaturesPleated media for high dirt holding capacityReinforced with epoxy coated steel wire on both sides of cloth40 – 50% increased dust loading capacity with prefilter (part number suffix P)Optimal surface area per given sizePolyester Media BenefitsWashable with lukewarm water & mild detergentLess maintenance due to longer durabilityMoisture resistantHandles hot air and oil mist from unload cycle of reciprocating/piston compressorCleaning Solberg Filter ElementsSolberg filter elements should be cleaned or replaced once the pressure drop reaches 10 to 15-inches water column (250 – 380mm WC) above the initial pressure drop of the installation. Please note that the overall performance of a filter element is altered once cleaned; the initial pressure drop after cleaning will be greater than the original, clean pressure drop of the element. After each subsequent cleaning, the initial pressure drop will continue to increase. Under all circumstances, the initial pressure drop of the element needs to be maintained at less than 15-inches water column (380mm WC). Cleaned elements that exceed 15-inches water column (380mm WC) at start-up should be replaced with new elements.Paper Element: The paper element may be lightly blown with low pressure air. It is disposable and in most cases should be replaced with a new element.Polyester Element: The polyester element may be washed in warm soapy water, vacuumed, gently blown out or replaced. Use a mild detergent like Dawn liquid soap.  The element should be completely dry before reinstallation. The element should be replaced after a maximum of three cleanings.Polyurethane Prefilter: The prefilter may be washed as a sponge or replaced to give the element a longer service life.Epoxy Coated Wire Mesh and Stainless Steel Wire Mesh Elements: Cleaning instructions similar to polyester, except mild solvents may be used.

Recommended Products For Solberg


Solberg CSL-850-201HCB Vacuum Filter
Solberg 375P Polyester Replacement Filter
Solberg CSL-850-200HC Vacuum Filter
Stenflex 11375700 AS-1 DN300 NBR PN16 BL200 PN16 Rubber Expansion
Grundfos SP60-19 Pump With Motor
KWD HEK 080 Coupling
Vogel 341-200-10000-00 Single-line - Piston Metering Device
Steimel SF2/3 Gear Pump
Gorter Controls HSV086 Safety Cutoff Valve
Voith IPS 5/-50/ 101 Pump
Vogel MKU5-12BB00000 428 Single Line Pump
Scherzinger 5040-350-B-DM-300-4 Hastelloy (R) Gear Pumps 5040
Goldammer NTR 85-SR30-T1-A-FE-L370-01-L1/250/S-T90Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Mp Filtri MPF1002AG3P25NB Filter
Revere HPS-60kg-C3 Single-Point Load Cell
MBS MLU 323 114 18 US 2000 Multiflo Heat Exchanger
Skf 501-303-029 Pump Unit
Grundfos NK 100-160/160-140 BA1F2AESBAQEIW3 Pump
Hansa-TMP F90300N034 Flanges and Pipe Fitting
Honsberg HD2K-025GM060E+OMNI-HD-2KIS Flow Meter / -switch
Officine Orobiche IVF Series-SLE 32 Visual Flow Indicator
Hengstler AC58/0010EK.42OLB Absolute Encoder
Goyen RCAC25FS4022 Diaphragm Valve
Asco G356C150S19FLF1 Compact Valve
CKD CMK2-CC-40-175-J Cylinder
Grundfos 98666397 CM10-4 A-R-G-V-AQQV F-A-A-N Pump
HEIDENHAIN LIC 4195 Y Exposed Linear Encoder