im-tek.com

Solberg CSL-850-200HC Vacuum Filter

Solberg

Product Code: CSL-850-200HC
Brand: Solberg



GET OFFER: info@imtek.com.tr

Description for Solberg CSL-850-200HC Vacuum Filter

Product DescriptionSolberg Polyester 375P Filter Element with PrefilterElement Rating: 1500 SCFMSurface Area ft2: 28Inner Diameter: 8″Outer Diameter: 11 3/4″Height: 14 1/2″Endcap: Galvanized metal endcaps with neoprene gaskets on open end(s)Filtration: Polyester, 99%+ removal efficiency to 5 micronTemp (continuous): min -26°F (-15°C), max 220°F (104°C)Filter change out differential: 15-20″ H2O over initial Δ PSolberg Filter Element FeaturesPleated media for high dirt holding capacityReinforced with epoxy coated steel wire on both sides of cloth40 – 50% increased dust loading capacity with prefilter (part number suffix P)Optimal surface area per given sizePolyester Media BenefitsWashable with lukewarm water & mild detergentLess maintenance due to longer durabilityMoisture resistantHandles hot air and oil mist from unload cycle of reciprocating/piston compressorCleaning Solberg Filter ElementsSolberg filter elements should be cleaned or replaced once the pressure drop reaches 10 to 15-inches water column (250 – 380mm WC) above the initial pressure drop of the installation. Please note that the overall performance of a filter element is altered once cleaned; the initial pressure drop after cleaning will be greater than the original, clean pressure drop of the element. After each subsequent cleaning, the initial pressure drop will continue to increase. Under all circumstances, the initial pressure drop of the element needs to be maintained at less than 15-inches water column (380mm WC). Cleaned elements that exceed 15-inches water column (380mm WC) at start-up should be replaced with new elements.Paper Element: The paper element may be lightly blown with low pressure air. It is disposable and in most cases should be replaced with a new element.Polyester Element: The polyester element may be washed in warm soapy water, vacuumed, gently blown out or replaced. Use a mild detergent like Dawn liquid soap.  The element should be completely dry before reinstallation. The element should be replaced after a maximum of three cleanings.Polyurethane Prefilter: The prefilter may be washed as a sponge or replaced to give the element a longer service life.Epoxy Coated Wire Mesh and Stainless Steel Wire Mesh Elements: Cleaning instructions similar to polyester, except mild solvents may be used.

Recommended Products For Solberg


Solberg CSL-850-200HC Vacuum Filter
Solberg CSL-850-201HCB Vacuum Filter
Solberg 375P Polyester Replacement Filter
Eurotherm 2604/VH/1XX/XX/D4/G5/RR/XX/XX/XX/XX/XX/ENG/XXXXX/XXXXXX/XX/XXX/XX/SPID/XXXX/XXXX/S/X/X/XXX/1HA/XXX/ Controller Eurotherm 2604/VH/1XX/XX/D4/G5/RR/XX/XX/XX/XX/XX/ENG/XXXXX/XXXXXX/XX/XXX/XX/SPID/XXXX/XXXX/S/X/X/XXX/1HA/XXX/ Controller
WARNER ELECTRIC ARC Magnetic Capping Headsets and Chucks
Alfa Laval 9612628650 LKB F 25/1
Topworx 11-1111000 - 3/8 Side Sensing Spdt Brass with Black Lacquer Coating Model 11 Go Switch
Elcis 149C I05 - Series for motors
Stauff SM-322-PP-IS-M-W5 Tube Clamp
MBS MLI 88 3000 Industrial Crossflo
Aignep SOLU1 SOLENOID 22 MM UL1446 CAN/CSA C22.2
Gefran LT-H-0350-P L000X000X0N Potentiometer
KSB MCPK125-080-250 GC KP2 A Pump
Alfa Laval TE67EA21111230 PT: 0 to 40 bar 0,1% FS Clamp 2",plug M12,N/A
Eltra EA58C2048G8/28SXX10X6MCA 8-28V Encoder
Sitema FSKP 25-Z FSKP 025 11 Power Stroke
PCM EDSA-10410 Static Mixer
Brinkmann BGL/SBG802 Horizontal End-Suction Pump
Gefran LT-M-0500-S L000X000X0N Potentiometer
Eaton DU251-0017 Duplex Filter
Loreme CAL4/100IG4 Signal Isolator
Böhmer FSK R 025.125 Ball Valve
Faulhaber 1645S048BHS Brushless DC-Servomotor
Officine Orobiche IVF Series-SPD 20 Visual Flow Indicator
Gefran PC-H-0050 L000X000D0N Potentiometer
Scherzinger 4030-710-B-DM-110-2-Exe Stainless Steel Gear Pumps 4030
ISO IPN-160 Switch